Maintenance / care
Before any work on the device:
Switch off the device and unplug.
¾
Wait until the device is at a standstill.
¾
Ensure that the device and all air
¾
tools and accessory parts are depres-
surised.
Allow the device and all air tools and
¾
accessory parts to cool.
After any work on the device:
Start up and check all safety devices.
¾
Ensure that there are no tools or
¾
similar on or in the device.
Advanced maintenance and
¾
repair work as described in this
chapter, must only be carried out by
specialists.
Note
Maintenance and inspections must be
planned and performed according to
the legal regulations dependent on
the set-up and operating mode of the
device.
Supervisory authorities can request the
submission of corresponding documenta-
tion.
Before each use
▸
Inspect air hoses for damage, replace as neces-
sary.
▸
Check screw connections are tightly seated,
tighten as necessary.
▸
Check the supply cable for damage; if necessary
arrange replacement by an electrician.
DANGER!
Daily
▸
Drain the pressure tank condensation at the
condensate drain [12].
Every 50 operating hours
▸
Clean the air filter [9] (Fig. IV).
Every 250 operating hours
▸
Clean or replace the air filter [9] (Fig. IV).
After 1000 operating hours
▸
Arrange for inspection in a specialist workshop.
Note
The service life of the device will be
significantly extended by adhering to the
maintenance intervals and performing
the scheduled maintenance work.
Storage
Attention!
Do not store the device outdoors or in a damp
¾
environment.
Frost (< 5 °C) will destroy the device and
¾
accessories, as these always contain water. If
there is a risk of frost, dismantle the device and
accessories and store protected against frost.
▸
Switch off the device and unplug.
▸
Depressurise the pressure tank and all connected
air tools.
▸
Drain the pressure tank condensation at the
condensate drain [12].
▸
Store the device so that it cannot be started up by
unauthorised persons.
23