SPACE HEATER 5 kW
GB
Operating Instructions
Connection
Connect space heater to mains supply through plug. Be sure to mount plug correctly.
Operation
Switch on unit and start space heater by adjusting the function switch (1) to the position required:
1/2 (2.5 kW)
1
In general
The space heater is equipped with an adjustable thermostat. The temperature required is set by means of the adjustment button
(2) after which the heater runs automatically. Before switching off the heater, it is recommended to interrupt the heating elements
and to change over to Fan for a couple of minutes in order to cool the unit before switching over to Off or before interrupting the
mains supply. If, however, the heater is interrupted by means of the main switch or if the current falls out and the thermal cut-out
is thereby activated, RESET (3) thermal cut-out when the heater has been cooled off.
PV Version (Post Ventilation)
Each time the heating elements are turned off (heating temperature reached) by the thermostat it results automatic fan opera-
tion within 3 minutes
WARNING !
Do not cover! Danger of fire, if the equipment is covered.
Minimum distance from inflammable materials: 0.5 m!
Do not use the heater in the immediate vicinity of washbasin, bath, shower and swimming pool!
Do not use the heater in fire hazardous rooms!
Do not use the heater outdoors in rainy weather!
Do not place the heater directly under a mains outlet!

Fixed installation

When making a fixed installation the drawing must be
followed (figure 1).
Maintenance
Clean the space heater with compressed air when it is
disconnected from the mains.
VARANTEE
KEEP VALID RECEIPT OR GUARANTEE CARD
To obtain guarantee cover within the guarantee period, it
is an absolute MUST that either a valid receipt or the
guarantee card is submitted to the service center together
with the appliance.
1/1 (5 kW)
O
3
Fan
MAX
RESET
MIN
2
Ceiling
min. 0.5 m
Wall
min.
0.5 m
min. 1.8 m
Floor
Figure 1
Type 1550 / 1551 / 1556
Off
O
min.
15 cm
Wall
7