en
ENGLISH
- Clean the filter in the compressed air connection
at least once a week.
- It is recommended that you install a pressure
reducer with a water separator upstream of the air
tool.
- If a large amount of air or oil is escaping, check the
air tool and have it maintained if necessary. (see
Section 9.)
- Avoid contact with dangerous substances that
have accumulated on the tool. Wear suitable
personal protective equipment and take appro-
priate measures to remove any dangerous
substances before maintenance.
f
8. Accessories
Use only genuine Metabo accessories.
Only use accessories that are designed for this air
tool and that fulfil the requirements and the specifi-
cations listed in these operating instructions.
For a complete range of accessories, see
www.metabo.com or the catalogue.
9. Repairs
Danger! Repairs to air tools must only be
carried out by qualified specialists, using orig-
inal Metabo spare parts!
If you have Metabo air tools that require repairs,
please contact your Metabo service centre. For
addresses see www.metabo.com.
You can download spare parts lists from
www.metabo.com.
10. Environmental Protection
Observe national regulations on environmentally
compatible disposal and on the recycling of disused
air tools, packaging and accessories. You must not
cause risks to people or the environment.
Use non-polluting lubricating greases.
To prevent any grease from entering the environ-
ment, do not allow it to drip uncontrollably.
11. Technical Specifications
Explanatory notes on the specifications on Page 3.
Subject to change in line with technological
advances.
V
= Air requirement per stroke
1
p
= Maximum permissible supply pressure
max.
A
= Dimension: Length x Width x Height
m
= Weight
The technical specifications quoted are subject to
tolerances (in compliance with the relevant valid
standards).
Emission values
Using these values, you can estimate the
emissions from this tool and compare these with the
values emitted by other tools. The actual values
may be higher or lower, depending on the particular
application and the condition of the tool or mounted
12
tool. In estimating the values, you should also
include work breaks and periods of low use. Based
on the estimated emission values, specify protec-
tive measures for the user - for example, any organ-
isational steps that must be put in place.
Sound level (EN ISO 15744):
L
= Sound pressure level
pA
L
= Acoustic power level
WA
K
, K
= Measurement uncertainty
pA
WA
Wear ear protectors!