Tesira Amplifiers Rear
Amplifier Output Connections
CAUTION
All Speaker wiring connections should be made by qualified personnel and with the amplifier power removed. The 100V output
requires Class 3 wiring. Please refer to a qualified electrician or other qualified person according to local codes.
Speaker Connection
To minimize power loss, use a speaker cable of appropriate gauge for the load impedance. For long
speaker cables, to minimize high frequency loss, choose a low capacitance cable. Use the supplied plug-
in barrier strip connectors to connect loudspeaker level outputs. If stranded speaker wire is used, be sure
to incorporate all strands into the connector, as stray strands can short to the adjacent terminal or
chassis. Do not leave excessive bare wire outside the terminals, as this can lead to shorts. Use of the
supplied cable restraints is required to secure the cable in the connector. To facilitate parallel wiring, each
connector allows for the connection of two loads to each amplifier channel.