INSTaLLaTION INSTRUcTIONS

Water Supply
Hot Water Temperature
Working Pressure
In case of pressures over 5 BAR (~75 PSI), we
recommend to use a pressure reducer.
Before proceeding with the assembly, purge
the hot and cold water pipes so as to avoid the
accumulation of dirt and impurities that could
affect the function of the faucet.
fIG. 01
Remove the protection covers (1.A) using a
screwdriver. Use the plug (1.B) if necessary.
fIG. 02
Fit the faucet body to the wall with the shower
outlet pointing upwards, connect the hot water
supply to the left inlet and the cold water supply
to the right one.
The depth of the wall niche must correspond (wall
coating included) to the tolerance given by the
MIN/MAX references given on the plastic cover
(2.A). Once all connections have been carried
out, activate the faucet at the working pressure
(we recommend maintaining the water flow for a
few minutes so as to purge the system from any
debris and/or dirt inside the piping). Temporarily
remove the protection cover (2.A) to check if there
are leakages and if the system works regularly,
reinstall the protection cover (2.A) and finish the
external wall surface.
fIG. 03
Remove the protection cover (2.A) as shown in
FIG. 02. With a screwdriver turn the stop cocks
(3.F) clockwise, loosen the fitting screw (3.E)
using the proper wrench and pull out the test plug
(3.D). Install the o-ring (3.C) and the sleeve (3.B)
on the thermostatic body. Use a small quantity of
the special grease included to lightly lubricate the
o-rings of the thermostatic cartridge (3.A). Insert the
cartridge in the faucet housing carefully aligning
the positioning hole with the housing of the fitting
Istruz. art. 8871100.indd 2
Recommended
Maximum
65 C° (~150F)
80 C° (~175F)
3 BAR (~45PSI)
5 BAR (~75PSI)
screw (3.E), then tighten the latter. Warning!, Do
not force the screw (3.E). Excessive tightening can
affect the correct function of the system or damage
it. The thermostatic cartridge is equipped with a
safety anti-scalding retainer set at 100°F (38°C).
For higher temperatures push the button on the
adjustment handle. In case of hot or cold water
pressure failure, the flow will automatically stop.
With a screwdriver loosen the stop cocks (3.F) in
anti-clockwise direction.
fIG. 04
Remove the protection tape of the adhesive
sponge (4.C) and apply it on the back of the plate
(4.B).
Fit the sliding flat washer (4.A) on the plate (4.B)
and install it on the thermostatic body till it is flush
to the wall.
fIG. 05
To install the handle, follow the instructions given
below:
Fit the handle (5.E) placing the spacer (5.F) on
the thermostatic cartridge without moving the bar
so as to not compromise the cartridge calibration.
Assemble the knob (5.D), fasten it with the screw
(5.B) inserting the flat washer (5.C) and install the
finishing cap (5.A).
fIG. 06
To replace only the handle and the knob (6.G-6.F)
follow the instructions given below:
Remove the cap (6.C), loosen the screw (6.D) and
the flat washer (6.E), then pull out the lever (6.F)
and the handle (6.G).
DO NOT move the cartridge bar (6.L) so as to
not compromise the calibration. Reassemble the
new handle and knob (6.G-6.F) and lock them
with the screw (6.D) inserting the flat washer (6.E),
complete by inserting the cap (6.C).
Minimum
15 C° (~60F)
0.5 BAR (~7PSI)