GAS 222.20 Denox
1 Introduction
This quick guide will assist you in starting up the unit. Follow
the safety notices or injury to health or property damage may
occur. Carefully read the original operating instructions in-
cluding information on maintenance and troubleshooting
prior to startup. These are located on the included CD and on-
line at
www.buehler-technologies.com
Please direct any questions to:
Bühler Technologies GmbH
Harkortstraße 29
40880 Ratingen
Germany
Tel.: +49 (0) 21 02 / 49 89-0
Fax: +49 (0) 21 02 / 49 89-20
These operating instructions are a part of the equipment. The
manufacturer reserves the right to change performance-, spe-
cification- or technical data without prior notice. Please keep
these instructions for future reference.
1.1 Intended Use
The sample gas probe is intended for installation into gas
analysis systems in commercial applications. Sample gas
probes are among the main components in a gas conditioning
system.
The area of application for DeNOx probes particularly spans
installation into DeNOx systems. The DeNOx probe allows for
targeted washing out of ammonia and its salts and, thus al-
lowing for low maintenance operation of downstream sample
gas conditioning. Another area of application is washing out
aerosols.
• Before installing the device, verify the listed technical
data meet the application parameters.
• Further check if all contents are complete.
Please refer to the nameplate to identify your model. In addi-
tion to the job number it also contains the item number and
model designation.
When connecting, please note the specific values of the
device, and the correct version when ordering spare parts.
1.2 Type plate
Example:
Manufacturer including address
Model designation
ID no., Item no.
Electrical supply
1.3 Contents
• 1 x Sample gas probe
• 1 x Flange gasket, screws and nuts
• Product documentation
• Connection- and mounting accessories (only optional)
BX460035 ◦ 04/2021
Sample Gas Probe GAS 222.20 Denox
2017 02230017 462225012001
230V 50 Hz
Read manual!
2 Safety instructions
The equipment must be installed by a professional familiar
with the safety requirements and risks.
Be sure to observe the safety regulations and generally applic-
able rules of technology relevant for the installation site. Pre-
vent malfunctions and avoid personal injuries and property
damage.
The operator of the system must ensure:
• Safety notices and operating instructions are available
and observed,
• The respective national accident prevention regulations
are observed,
• The permissible data and operational conditions are
maintained,
• Safety guards are used and mandatory maintenance is
performed,
• Legal regulations are observed during disposal,
• compliance with national installation regulations.
DANGER
Electrical voltage
Electrocution hazard.
a) Disconnect the device from power supply.
b) Make sure that the equipment cannot be reconnected to
mains unintentionally.
c) The device must be opened by trained staff only.
d) Regard correct mains voltage.
DANGER
Toxic, corrosive gases
The measuring gas led through the equipment can be hazard-
ous when breathing or touching it.
a) Check tightness of the measuring system before putting
it into operation.
b) Take care that harmful gases are exhausted to a save
place.
c) Before maintenance turn off the gas supply and make
sure that it cannot be turned on unintentionally.
d) Protect yourself during maintenance against toxic / cor-
rosive gases. Use suitable protective equipment.
DANGER
Potentially explosive atmosphere
Explosion hazard if used in hazardous areas.
The device is not suitable for operation in hazardous areas
with potentially explosive atmospheres.
Do not expose the device to combustible or explosive gas mix-
tures.
3 Transport and storage
The device should be only transported in the original case or
in appropriate packing.
Bühler Technologies GmbH
7