EN
AC Power
Junction Box
Wiring
DMX Linking
DMX Connection
Signal Wiring
DMX Junction
Box Wiring
From
Fuse
Panel
Distribution
The Ilumipod 18g2 IP Optic WW will work with a DMX controller using a
regular DMX serial connection. A DMX Primer is available from
www.iluminarc.com.
This product provides a DMX 512 connection by using bare-ended IP67-
rated signal cable. This cable comes connected to the product. See the User
Manual to connect and configure for DMX operation.
To provide the signal, you have two options:
·
Connect the bare-ended IP67-rated signal cable from the product to two
IP67-rated signal connectors (DMX In and DMX Out).
·
Use an IP67-rated junction box. If so, make sure to use IP67-rated
conduit.
The signal cable must match or exceed the electrical characteristics of
the Belden® 9841 cable for EIA RS-485 applications. You can also use
CAT 5, CAT 5e, or CAT 6.
Signal In
Junction Box
Ilumipod 18g2 IP Optic WW QRG
L :
Black
N :
White
G :
Green
Conduit
Box
1: Common (Shield)
2: Data – In (Black)
3: Data + In (White)
4: Data – Out (Green)
5: Data + Out (Red)
Conduit
3
Distribution
Box
Signal Out
Junction Box
To
Other
Boxes