E N G L I S H
INSTALLATION
The filter should be installed as close as possible to the swimming pool and preferably at a level of 0.50 meters below the
surface of the water in the swimming pool. Make sure there is drainage available to use.
IMPORTANT: Do not use an iron and hemp pipe for the selector valve connection, it is essential to use plastic
accessories and TEFLON tape. The pipe size connection on the multiport valve will be either 1.5" or 2" BSP thread.
Always leave enough space round the filter in order to perform the necessary examinations and maintenance during the
filter's life. The filter should have a minimum of 20 cm of free space around it for correct working.
ASSEMBLY
Follow the below points to correctly assembly the filter:
1.- Place the filter on a horizontal and clean surface.
2.- Place the filter in its final location.
3.- In case of a filter with a side mount valve, install the multiport valve on the filter. Make sure the connections between
the valve and the filter are correct.
4.- There are 3 connections to the multiport valve: from the pump, to the waste drain and back to
the pool. Each of these three connections are clearly identified on the multiport valve.
5.- Install the pressure gauge assembly and air purge (see exploded view). It is not necessary to use teflon tape, as the
watertightness is provided in this case by the joint. Do not tighten the T with a tool, as hand tight will be sufficient.
OC-1 LOADING
If OC-1 has not already been installed in your filter, fill the filter with the quantity of OC-1 as detailed on the filter sticker.
Procedure as follows:
1.- Fill with OC-1 when the filter is installed in position (See ANNEX I)
2.- Take off the lid (multiport valve if top mount)
3.- Pour the required quantity of OC-1 into the filter.
4.- Fix the filter lid / multiport in place and connect up the pipework as required.
4