hold the operation head with the other hand and
move the probe from up to down or from left to
right above the fat.
Avoid hip bone while operation. (If people suffer
from varicosity disease, please do not apply to
the treatment and need to inquire your doctor.)
During treatment please communicate with client
then adjust the intensity and mode accordingly.
SolutioN for SimPle failure
Failure
check whether the power wire
is in good connection with
Power on, the machine
mainframe
no rePonSe
check whether the power switch
is on
During the oPeration ,the
using for too long time, turn it off
machine iS overheat
and let it naturally cool down
check whether the power switch
is on
no Power
check the fuse, if it is broken,
replace it
imPortaNt Safety Notice
1. The machine is professional instrument for beauty
salon,in orderto avoid any unnecessary hurt,need
professional beautician tomake operation.
2. Do not disassemble the machine or operate the
machine that not Explained in the instruction book.
All the maintenance services shall be carried out
By the professional maintenance technician .
3. Do not install or operate the machine with wet
hands or near the water sources so as to avoid
the liquid spraying/swashing over the machine.
4. Pull out the plug and connect with the mainte-
nance services center in the Following cases:
•
A. Liquid spray/swash over the machine or
the machine get caught in rain or water.
•
B.The machine has peculiar smell,fume/
smog or abnormal noise
•
C.Instrument fell down or the shell damaged.
•
D.Power wire damaged or scratched.
5. Do not put any item on the power wires ,or ins-
6. Pull out the power wires at the end of use for the
7. Do not insert any type of item into the instru-
8. Do not out the instrument on the unstable tro-
Solution
9. To guarantee the life circle of this machine,the
10. The power shall comply with the specification
11. The company has right to revise or amend this
atteNtioN
If the power wire is damaged,it must be replaced by
manufacturer,its service agent or similarly qualified
persons in order to avoid a hazard.
This appliance is not intended for use by
persons(including children) with reduced
physical,sensory or mental capabilities,or lack of
experience and knowledge, unless they have been
given supervision or instruction concerning use of the
appliance by a person responsible for their safety.
Children should be supervised to ensure that they
do not play with the appliance.
Voltage
240/110 V
· 201 ·
tall the instrument in the place where its power
wires will be trampled.
sake of safety.
ment opening,otherwise there will be a fire or
electrical shock.In case of something fell into the
opening but you could not take it out ,please pull
out the power wires and connect with the dealer
or our Company.
lley, shelf or vehicle,if fall down,the instrument
maybe damaged .
interval of the continous switch on and off
should be over one minute.
specified in the label,otherwise the machine will
not work or work abnormally,even be burnt out.
manual.
The company reserves all the rights of interpre-
ting the information mentioned above.