2016 - 2017
VLC20 - VLC20B - VLC20BK
3-5KW
Instrument WITH PROGRAMMABLE TWO SYSTEMS OF CONTROL, PHASE-Angle or ZERO-CROSSING FAST
WITH PREHEAT in PHASE-Angle. RELAY STATIC and FUSE INCORPORATED. PROPER to CONTROL
Loads resistive Mono-phase 230V 4KW as Lamps Infrared IR.
-FASE-Angle :
*SOFT START 200mS AUTO SOFT START FOR MOMENTARY LACK OF THE TENSION OF LINE IT IS OF
FEEDING TOOL.
-ZERO CROSSING Fast with preheat :
*SOFT START in Face-Angle, mentenance for 5 Sec. After change in ZERO CROSSING Fast time of cicle 400mS.
PS: SOFT START and after ZERO-CROSSING fast , They are Proper to Reduce The EXTRACURRENT
Sprout (Also 15 Times Her CURRENT NOMINAL) for the lamps short-wave , this method allows to avoid
the breakup of the fuse and the semiconductor.
Technical :
*Power Supplies 240V AC/DC 2VA
*STATIC Relay 20A 230V AC 50hz.
*FUSE internal
25Amp.FF
*Mechanical interrupter ON-OFF controler.
*Case in METAL with accessories .
NOTES of USE:
Controler VLC20 Used In Covered Environments (IP20) Where The Temperature doesn't Overcome 40°C.
IT HAS TO BE CONNECTED UNDER A MAGNETO - THERMIC WITH DIFFERENTIAL.
PROGRAMMING METHOD:
-To Set the dispenser with function
PHASE ANGLE or ZERO CROSSING
FAST perform the following steps:
With the DOWN button to bring the value on
display to zero, while pressing DOWN
and UP will appear F (Phase Angle)
pressing DOWN again appear
Z (Zero Cross).
With DOWN you can alternate with F Z.
THE device after 5 seconds stores.
G3Power.it
230Vac two programming
CONTROL:
*RANGE: 0 - 100% 24 Steps. Linear in CURRENT.
*SAVE function in E2PROM.
*Alarm breaking fuse or load.
( ASTERISK APPEARS
DIMENSION:
RELAY STATIC and FUSE INCORPORATED
( cod. 1750 - 1752 - 1753 )
).
www.g3power.it
LEGENDA
1
= 4.3%
E= 60%
2= 8.5%
F= 65%
3= 13%
G= 69%
4= 17%
H= 73%
5= 21%
I = 78%
6= 26%
L= 82%
7= 30%
M= 86%
8= 34%
N= 91%
9= 39%
O= 95%
A= 43%
P=100%
B= 47%
ALARM
C= 52%
LOAD
........
. . . .
... . . .
. .
. . . .
PHASE
D= 56%
.
F
ANGLE
........
. . . .
. . . .
.. .
. . . .
.
ZERO
A= 43%
.
Z
CROSS
ITEM 1754