GB
Sensors for solar installation – package AD 160
Assembly and connection instructions
1
The sensor kit includes:
1
1 sensor for solar panel with connecting block mak-
ing it possible to connect to an extension lead (cross sec-
2
tion min. 2x0.75 mm
)
2
1 sensor for solar DHW tank (auxiliary sensor),
which makes it possible to measure the temperature of
the domestic hot water in the tank connected to a boiler
control panel.
1. Assembly
Refer to the instructions delivered with the control panel.
2. Connection
Connections are made to the terminals on the boiler con-
trol panel.
Refer to the instructions delivered with the control panel.
It is necessary to separate the sensor cables
from the 230V circuit cables.
In the boiler: For this purpose, use the 2 cable
clips located on various parts of the boiler.
Outside the boiler: Use 2 cable ducts or chan-
nels at least 10 cm apart.
2
8801N306
3. Technical Data
- Length of the sensor cables: 5 m
- Ohmic values of the sensors:
Sensor resistance
Temp.
solar exchanger
10° C
539 Ω
20° C
549 Ω
25° C
558 Ω
30° C
568 Ω
35° C
578 Ω
40° C
587 Ω
45° C
597 Ω
50° C
607 Ω
55° C
616 Ω
60° C
626 Ω
65° C
635 Ω
70° C
645 Ω
75° C
654 Ω
80° C
674 Ω
90° C
692 Ω
100° C
787 Ω
150° C
879 Ω
200° C
1 060 Ω
300° C
3
Domestic hot water
sensor resistance
19 691 Ω
-
12 474 Ω
10 000 Ω
8 080 Ω
5 372 Ω
3 661 Ω
2 535 Ω
1 794 Ω
1 290 Ω
941 Ω
-
-
-
-
-
-
-
-
-