CONFIGURATION
NAME
SIZE
VALUE
1
0x00 -> (Default) Turns off the center LED
Central LED
1
0xFF -> Turn on the center LED
0x0000 -> (Default) Disables custom consumption limit
2
Custom consumption limit
2
0x0001 - 0xFFFF -> Sets the power in Watts that is supported
(once the load is over, it is disabled).
0x00 -> (Default) Disables the beacon function
Beacon
3
1
0x01-0x63 (1-100%) -> Sets the intensity of the beacon LEDs.
0x00 -> (Default) Disables timing
10
On Timed
1
0x01-0x7F -> Sets a timing with a range of (1-127sec)
11
Off Timed
0x80-0xFE -> Sets a timing with range of (1-127min)
16
Delayed Off
0x00 -> (Default) Enables the pushbutton to control the load
Local lock
13
1
0xFF -> Disables the action of the pushbutton on the load
0x9867 -> Parameters, Groups and Z-Wave status are restored
Reset default
15
2
to the default values.
0x4312 -> Parameters, with the exception of Long Pulse Lock, are
reset to default values.
0x00 -> After a reset the load starts off
PostReset State
17
1
0xFF -> (Default) After a reset the load starts activated
0x00 -> TOGGLE (Default). A short press (t <2s) switches the
19
Action when pressing
1
load
0x01 -> ON. A short press (t <2s) activates the load
0x02 -> OFF. A short press (t <2s) deactivates the load
0xFF -> The central LED flashes for 5 seconds at a frequency of
Identify (Write Only)
20
1
0.1s
[Byte 0]
21
Charge status (Read only)
2
0x00 -> Charging is disabled
0x01 -> Charging is activated
[Byte 1]
0x00 -> Charging is disabled
0xFF -> Charging is activated
0x00 -> (Default) The long press (t> 2s) works as described in the
27
Long key press
1
usage and signaling table
0xFF -> Pressing 2s <t <10s does not send Node Info
Pressing t> 30s resets the configuration parameters except
Long Hold Lock and sends a Node Info
All These configurations are not restored to default when device is removed from ne-
twork. COMMAND_CLASS_DEVICE_RESET_LOCALLY -> DEVICE_RESET_LOCALLY_NO-
TIFICATION will be sent to inform controller that node has been removed from network, but
the device will keep the current configurations.
To restore the configurations values, please perform one of these actions:
- Use Command CONFIGURATION SET with default bit to 1 for each
configuration parameter.
- Perform Reset Default Action via keypad pressing or configuration command
default.