WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:
1. Use this unit only in the manner intended by the manufacturer. If you have questions, contact the manufacturer at the address or telephone number
listed in the warranty.
2. Before servicing or cleaning unit, switch power off at service panel and lock the service disconnecting means to prevent power from being switching on
accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel.
3. Installation work and electrical wiring must be done by a qualified person(s) in accordance with all applicable codes and standards, including fire-rated
construction codes and standards.
4. Sufficient air is needed for proper combustion and exhausting of gases through the flue (chimney) of fuel burning equipment to prevent backdrafting.
Follow the heating equipment manufacturer's guideline and safety standards such as those published by the National Fire Protection Association
(NFPA), and the American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE), and the local code authorities.
5. When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities.
6. Ducted fans must always be vented to the outdoors.
7. Acceptable for use over a tub or shower when connected to a GFCI (Ground Fault Circuit Interrupter) - protected branch circuit (ceiling installation
only).
8. This unit must be grounded.
CAUTION
1. For general ventilating use only. Do not use to exhaust hazardous or explosive materials and vapors.
2. This product is designed for installation in ceilings up to a 12/12 pitch (45 degree angle). Duct connector must point up.DO NOT MOUNT
THIS PRODUCT IN A WALL.
3. To avoid motor bearing damage and noisy and/or unbalanced impellers, keep drywall spray, construction dust, etc. offpower unit.
4. Please read specification label on product for further information and requirements.
5. Do not use in a cooking area.
CLEANING & MAINTENANCE
For quiet and efficient operation, long life, and attractive appearance - lower or remove grille and vacuum interior of unit with the dusting
brush attachment.
The motor is permanently lubricated and never needs oiling. If the motor bearings are making excessive or unusual noises, replace the
motor with the exact service motor. The impeller should also be replaced.
OPERATION
The fan and light can be operated separately. Use a 2-function wall control. See "Connect Wiring" for details.
ASSEMBLY INSTRUCTIONS
MOUNT DIRECTLY TO JOIST OR I-JOIST
Place the housing assembly in the opening so the bottom edge is flush with the
finished ceiling. Nail the housing assembly to the joist using nails.
POSITION THE HOUSING ASSEMBLY
Position the housing assembly against the joist. With a pencil, trace an outline
of the housing assembly onto the ceiling. Set the housing aside, and cut out an
opening for the fan.
Note:hold the housing position 5/16" above the ceiling edge.
CONNECT ELECTRICAL WIRING
Run 120 V AC house wiring to the location of the fan. Use only UL-approved connectors (not included) to attach the house wiring to the wiring plate. Refer
to the wiring diagram, and connect the wires as shown.
LIGHT
SWITCH
FAN
SWITCH
BLK
LINE
WHT
IN
GRD
SWITCH BOX
READ AND SAVE THESE INSTRUCTIONS
Installer: Leave this manual with the homeowner.
BLU
LIGHT
WHT
BLK
FAN
WHT
UNIT
VENTILATION FAN
BLACK(BLK)
BLUE(BLU)
LIGHT
FAN
SWITCH BOX
POWER SUPPLY
120V AC
Model:
MC704L
Housing
Ceiling
5/16in.
WHITE(WHT)
GROUND (GRD)
WIRE
UNIT
PANEL
FAN
RECEPTACLE
LIGHT
RECEPTACLE