Amana D965E Manual Del Uso Y Cuidado página 7

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

4. Check that the rubber seal ring is seated correctly in the end
of the drain hose.
A. Drain port
B. Rubber seal ring inside drain hose
5. Insert the drain hose into the drain port. Turn the drain cap
clockwise to tighten.
6. Place the other end of drain hose into a floor drain. Check
that the drain hose lies flat and is in the drain.
Option 3—Connect Drain Tube to Drain Pump
(Models D965PE and D965PE-E Only)
If you plan to run your dehumidifier continuously, and you need a
longer drain hose or the drain location is above the dehumidifier,
you may want to attach the 16 ft (4.9 m) long drain tube
(provided) to the drain pump connector on the back of the
dehumidifier. When the water level inside the bucket reaches the
correct level, the drain pump automatically pumps the water to
the drain.
All manuals and user guides at all-guides.com
A
B
C
D
C. Drain cap
D. Drain hose
1. Remove the drain hose and drain tube from the dehumidifier
bucket.
A
A. Drain hose (3 ft [91.4 cm] length)
B. Drain tube (16 ft [4.9 m] length)
2. Insert the drain tube fitting into the drain pump connector
located on the back of the dehumidifier.
3. Push the drain tube fitting in as far as it will go.
4. Check that the drain tube fitting has snapped into position.
5. To remove the drain tube, press the button above the drain
pump connector while pulling the drain tube fitting away from
the drain pump connector.
B
7

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

D965e-eD965peD965pe-eD974e

Tabla de contenido