2.3. Maintenance

Cleaning and routine maintenance
Empty the condensed water container
1. Hold and pull out the condensed water
container with two hands;
2. Tilt the condensed water container,
pour out the condensed water into a basin;
3. Install the condensed water container.
WARNING:
1. Empty the condensed water container after each use. Any ongoing programme
will be paused and the Full LED lit if the condensed water container is full during the
drying process. After the container is emptied, the dryer can be restarted by pressing
the [Start/Pause] button.
2. Do not drink the collected water.
3. Do not use the dryer without the condensed water container.
Clean the filter door
1.Open the door.
2.Take out the filter door.
3.Clean the filter door; wipe off the scrap
threads accumulated on the filter door.
4.Reinsert the filter door.
Clean filter base
1. Open the maintenance cover.
2. Untighten both locking leavers
towards each other.
3. Clean the filter base completely.
4. Re-insert the filter base!
5. Tighten both locking levers.
6. Push the maintenance cover closed
until it locks into position.
Lock lever
NOTE!
1. The fluff accumulated on the filter will block air circulation, which will prolong
drying time and increase energy consumption;
2. You must disconnect the power cord before cleaning!
3. You must not operate the dryer without the filter!
4. Clean the filter after each use to prevent lint accumulation inside the dryer.
14
Filter door
Filter base
Maintenance
cover
tumble dryer
Clean heat exchanger
As necessary (approx. once every 2 months) remove the fluff
from the heat exchanger using the sponge or a soft brush.
When doing this, please use gloves.
Note: The fluff can be removed more easily if it is first
dampened e. g. with a laundry dampener.
Wash air condenser
>
Let the dryer to cool down.
>
Residual water may escape, place an absorbent
cloth under the maintenance cover.
1. Unlock the maintenance cover.
2. Fully open maintenance cover.
3. Tighten both locking levers towards each other.
4. Pull out the air condenser.
5. Clean the air condenser completely and drain it
thoroughly.
6. Clean the seals.
7. Re-insert the air condenser, handle at the button!
8. Untighten both locking levers.
9. Close the maintenance flap until it locks into position.
Please clean the air condenser approx. once every 3 months if
frequently used. Do not damage the air condenser!
A. Clean with water only; do not use hard/sharp-edged
objects!
Do not operate the dryer without the air condenser!
B. During drying, water may collect between the window
and the seal, but this does not affect your dryer's working
condition!
To ensure your and your family's safety, if your home power
supply does not meet the above-mentioned requirements
please make the necessary improvements immediately.
Model
Current
KDM2740
10A
KDM2740
16A

2.4. Troubleshooting

Display
Reason
Container is full
"Full" LED on permanently
Water pump failure or water
level sensor failure
Child Lock + 9h
Temperature sensor failure
Child Lock + 6h
Humidity sensor failure
Child Lock + 3h
Heater failure
EN
KDM2740
Solutions
Empty the condensed water
container
Please contact your local service
centre if the problem persists
15