Tabla de contenido

Publicidad

8. Mensajes de error

Error
Logging
message
number
Err01
1
Err04
4
Err06
6
Err11
11
Err13
13
Err14
14
Err15
15
Err16
16
OiLPr
90
tLtSE
91
----- *
92
2
OLOAD*
93
1
dLOAD
94
OLOAD*
95
1
OLOAD*
96
1
Meaning
Input signal unstable
Err01 (oil pressure)
Manual zeroing outside range
Err04 (oilpressure)
AD signal too high
Err06 (of oilpressure sensor)
Input signal unstable
Err11 (moment sensor)
Zero tracking out of range
Manual zeroing outside range
Err14 (moment sensor)
Compensated zero out of range
AD signal too high
Err16 (of moment sensor)
Connection error of the oilpressure
sensor
Connection error of the moment sensor
Underload
Overload on maximum weight
Dynamic overload
Overload on maximum moment
Overload on maximum weight and
moment
MANUAL DE INSTALACIÓN – RAVAS-SafeLoad
Action
Service call
Press CE-key
Try removing the
weight from the forks
before using the zero
key. If there is no
weight on the scale
contact your service
dealer
Service call
Service call
Check P049 of
moment settings
Service call
Press CE-key
Try removing the
weight from the forks
before using the zero
key. If there is no
weight on the scale
contact your service
dealer
Increase P019 an/or
P020 or perform a
new zero calibration
Service call
Service call
Service call
Lift the forks from the
ground
Remove the weight
from the forks
Reduce weight on the
forks or omit impacts
Remove the weight
from the forks or
replace the weight
more to the vertical
part of the forks
Remove the weight
from the forks
36