13
Operation
A short press on the UP or DOWN push button will rise or descend the roll-down shutter. After the set switch-off delay the module
will switch off automatically.
Stop the shutter at any time by pressing a push button of the opposite direction.
Maintaining the UP or DOWN push button pressed will move the shutter until the push button is released or the switch-off delay
has expired.
Pressing the UP and DOWN push buttons simultaneously will switch off the shutter motor.
Pressing the immediate UP push button will rise the shutter completely even if it was descending.
Pressing the immediate DOWN push button will descend the shutter completely even if it was rising.
The up and down commands will be operated through a single push button as from firmware version 0805. Operate this push button
to move the blind, operate again to stop the blind, operate again to move the blind in the opposite direction. Press and hold the push
button and release to stop the blind motor.
Learning mode:
Only push buttons connected to the Velbus via a push button interface or a control panel are appropriate for the procedure below. Follow-
ing push buttons can be learned: up, immediate up, down and immediate down. Each command can accept up to 14 different push but-
tons. As from firmware version 0805 you will also be able to learn push buttons which will raise and lower the blind. The number of push
buttons per command group has been narrowed down to 11.
4