SOLUTIONS IN CASE OF PROBLEMS
If there is a problem with your product, please refer to the diagrams below and the solutions table.
Ref : HYB01-5
Ref :
HYB01-10
LED
green
LED
red
Functions
Green led
Initial state
Blinks once
Flashes
Connected
quickly
Flashes slowly
Normal recharge
and steadily
End of recharge
LED fixed
Abnormal
LED off
communication
Under pressure
LED off
Over voltage
LED off
Leak
LED off
Over current
LED off
Power plug /
LED off
PCB overheating
The earth socket
/
is not connected
Power-on self-
LED off
test failed
Red led
Encountered problem
Blinks once
Connection problem
Connection problem
The voltage detected at the
LED off
input of the transmission box
is 12 V
Connection problem
The voltage detected at the
LED off
input of the transmission box
is 6 V
Connection problem
The voltage detected at the
LED off
input of the transmission box
is 9 V
The voltage detected at the
Flashes once
input of the transmission box
every 2 seconds
is abnormal, the charger then
enters a protection state.
When the voltage detected at
the input of the transmission
Flashes twice
box is less than 75 V ± 10 V
every 2 seconds
for 0.1 second, the output
current is cut off.
When the voltage detected at
Flashes three
the input of the transmission
times every 2
box is greater than 270 V ± 10
seconds
V for 0.1 second, the output
current is cut off.
When the current detected at
Flashes four
the input of the transmission
times every 2
box is greater than 25 ± 5
seconds
mA, the output current is cut
off.
The current detected at the
input of the transmission box
is between the overcurrent
value of 12 Ah and 14 Ah.
After the first detection, the
charger turns off for 5
Flashes five
seconds.
times every 2
After a new test, if the
seconds
transmission box encounters
the same problem, it will
deactivate for 10 seconds.
After 3 times of repetitions,
the red light comes on and the
load is cut off.
When the temperature of the
power plug or the printed
Flashes six times
circuit is above 85
every 2 seconds
period of 2 seconds, the
charger switches off.
Charging takes place but the
Led on
warning light will stay on.
Flashes eight
The charging cable is unable
times every 2
to charge.
seconds
17
Solution
Unplug and re-plug your
charging cable.
Unplug and re-plug your
charging cable.
Unplug and re-plug your
charging cable.
Unplug and re-plug your
charging cable.
Unplug and re-plug your
charging cable.
When the voltage detected at
the input of the transmission
box returns to normal, the
charger will automatically
operate again.
Unplug and re-plug your
charging cable.
When the voltage rises to 90V
± 10V, the recharging system
restarts after a delay of 5
seconds.
Unplug and re-plug your
charging cable.
When the voltage drops below
254 V ± 10 V, charging will
resume after a 5 second
delay.
Unplug and re-plug your
charging cable.
Once the fault is resolved, the
charger will need to be
powered on again to continue
charging.
Unplug and re-plug your
charging cable.
Unplug and re-plug your
charging cable.
It must wait for the
for a
temperature to drop below 65
for a period of 2 seconds to
return to normal operation.
Please contact a professional
to check your electrical
installation.
Unplug and re-plug your
charging cable.