inSTALLATion
The kit consists of:
—
2 four-output 16A through modules 1071/14 (50 and 51)
—
1 four-output 16A relay module 1071/13 (80)
—
2 eight-input modules for 1071/18 buttons (1 and 2)
—
1 seven-input on DIN rail module 1071/7 (30)
—
1 power unit 1071/20
The kit does not need to be programmed.
Simply insert the two terminals on the ends of the bus or on the two longer segments in
case of star configuration.
The installation diagram, referred to three rooms (A, B, C) is shown on the previous pages.
In case of two 1071/18 modules, the coloured wires for connecting the buttons must not
be extended otherwise the device will not work.
If only three buttons on a plate are used (so that 503 flush-mounting boxes can be employed), it is advisable
to eliminate the third button to preserve the all lights off scenario (available by pressing the fourth button
for longer than 1 second).
In order to make the installation more compact, double buttons accommodated in a two-module flush-
mounting box or round flush-mounting box (60 mm diameter) can be used as shown in the figure (Room
B).
Feedback can be provided by means of LEDs if Simon Urmet buttons are used
Multiple 1071/501 kit may be installed in the same apartment but the kits must not be connected to one
another.
A light control kit 1071/501 and a shutter control kit 1071/502 can be installed in the same apartment and
connected to one another, if required, via respective IPerBus segments. In this case, only two 1071/20
power units may be used and IPerBus must be appropriately ended with two only terminals.
The light kit 1071/501 can be used as a starting point for making a larger home automation system.
Programming using a PC and IPerSet software is needed to add further modules.
ELECTriCAL SPECiFiCATionS
—
Total bus consumption: 23 CU (considering full use of all 12 output points).
—
Bus terminal configurable by means of TERM jumpers available on all modules. Insert only two terminals
on the IPerBus ends, or two terminals on the longer branches in case of star configuration.
—
Relay outputs:
For two 1071/14 modules:
Resistive loads
16 A
3680 W
(1) This function is available for buttons connected to the two 1071/18 modules only. It is not available for buttons
connected to the 1071/7 module.
1
Controllable loads, 220-240 V~ (distributed on the four relays)
Incandescent
lamps
10 A
2300 W
Fluorescent and
energy-saving
lamps
4 AX
920W
.
(1)
Electronic
Ferromagnetic
transformers
4 A
920W
transformers
4A
920 VA