Technical data
Type
Supply
Power consumption
Nominal force
Nominal locking force
Service life
Duty cycle
Housing
Ingress protection
Temperature range
Nominal stroke length
Additional functions:
Running speeds and forces
* + approx. 20 % cut-off reserve (temporary)
Closing edge protection
In "CLOSE" direction the drive has an active
protection for the main closing edge. With an
overload in the closing range 3 and 2 the drive runs
"OPEN" for 10 seconds, then drive "CLOSE" again. If
after three attempts a closing is not possible, the
drive remains in this position.
In addition, the drive has a passive clamping
protection. The closing speed in closure Range 2
and 1 is reduced to 5 mm/s.
Higher forces can occur on besides
closing edges. Danger of violent
pressure in handaccessible area.
6/16
KA 34-K / KA 54-K
KA 34-K
230 VAC / ±15% / 50 Hz
24 W / 40 VA
300 N
2000 N (per drive)
>10 000 double strokes
30 % (with cycle time 10 minutes)
Aluminium, anodized
IP 32
(with covering stoppers delivered with bracket sets)
-5 ... +75°C
see type plate
Closing edge protection activated (3 stroke repeatings), locking relief activted
English
KA 54-K
230 VAC / ±15% / 50 Hz
32 W / 52 VA
500 N
99.823.91 2.0/04/11