LOGO! 8 TP EduTrainer
– Operating instructions
7.3 LOGO! DM8 12/24R
Technical data LOGO! DM8 12/24R expansion module
Supply power
Input voltage
Permissible range
Digital inputs
Number
Electrical isolation
Input voltage L+
Input current for
Delay time for
Digital outputs
Number
Type of outputs
Electrical isolation
In groups of
Short-circuit proof
Control of a digital output
Switching capacity of the outputs at lamp load,
max. output current
for signal "1" nominal value 5 A
for signal "1" minimum load current
Parallel connected outputs for increased power
Switching capacity of the contacts
with inductive load
with resistive load
Switching frequency
Mechanical
Ohmic load / lamp load
Inductive load
Please refer to expansion modules for the LOGO! 8 manual for further information.
30
12/24 V DC
10.8 – 28.8 V DC
4
No
signal 0
< 5 V DC
> 8,5 V DC
signal 1
< 0,88 mA
signal 0
> 1,5 mA
signal 1
0 to 1
Approx. 1,5 ms
1 to 0
Approx. 1,5 ms
4
Relay outputs
Yes
1
No
Yes
1000 W
5 A
100 mA
No
max. 3 A
max. 5 A
10 Hz
2 Hz
0.5 Hz
© Festo Didactic 8086581