Operating manual BDC-3155HCA
Wiring diagrams
1.
Plug
2.
Vacuum cleaner
3.
Circuit breaker
Item
Circuit breaker
Q1
Box for Q1
GB
Figure 18
BDC-3155HCA
Part
400V
4083901540
Z8 39969
Additional Information
■
Asbestos vacuum cleaners (in accordance with German
specification TRGS 519)
1. After the asbestos vacuum cleaner has been used in
contaminated zones as established by TRGS 519, it
cannot be used in a healthy environment. Exceptions
are permitted if the asbestos vacuum cleaner has
been completely decontaminated (not just the outer
casing but also the air cooling zone, the casings
where the electric components are assembled
(electric panels), the electric components themselves,
etc.), by qualified personnel in compliance with TRGS
519 N. 2.7.
This activity must be reported and recorded in writing
by qualified personnel.
2. The filters must be replaced in suitable places (e.g. a
decontamination station) by qualified personnel.
3. The filter must only be replaced by qualified
personnel in accordance with the instructions given in
this manual.
4. When the asbestos vacuum cleaner is being handled
and transported, always close the inlet with the
relevant plug. If the vacuum cleaner is transported
outside the contaminated zone, it must be cleaned as
described in point 1.
Alternatively, the asbestos vacuum cleaner must be
carefully closed in a sealed hermetic bag.
This activity must be reported and recorded in writing
by qualified personnel.
5. Fitting the drain hose: insert the hose into the air
outlet on the special panel supplied. Fully tighten the
supplied screw clamp making sure that the hose is
unable to slip off.
[ NOTE ]
Also refer to the "Maintenance, cleaning and
decontamination" paragraph of this manual for more
details about points 2, 3, 4.