Electric Heating Element
Safety requirements — installation
1. Fitting and connection of the heating element should only be performed
by a qualified installer.
2. Connect the unit to a sound electrical installation (see the ratings on the
heater).
3. Switching on the heating element in the open air to test the device is per-
mitted for a maximum of 3 seconds.
4. Never test a heating element that is already in- stalled. Do not turn the
heating element on in an empty radiator!
5. Ensure that the power cord does not touch the hot parts of the heating
element or radiator.
6. Before installing or removing the device, make sure it is disconnected
from the power source.
7. Do not open the device — any interference with internal components
will invalidate the warranty.
8. The heating element's power output must not exceed the radiators pow-
er output for the parameters 75/65/20° C.