If you do not enable this feature, power will flow through the
controller as usual when you disconnect from CPWI.
- Save Data
This feature allows you to export the raw data from the controller in
l
a .CSV format, which you can open in Microsoft Excel or Google
Sheets. If you select this option, you can find the saved .CSV file
in this folder on your PC: Documents\Celestron\CPWI
To disconnect from the Smart DewHeater Controller 2x at the
end of an observing session, you can either close CPWI and the
Application Shutdown window will appear (Figure 20), or you can
select the "Connection" icon in the upper left corner and select
"Disconnect." If you have selected "Power Down on Disconnect"
from the Dew Heater>Settings menu, all devices connected to the
controller will turn off. Otherwise, power will continue to flow through
the controller's ports as usual.
Fig 20
Application Shutdown window
9. Specifications
Weight: 1.2 lbs.
Dimensions: 5.5" x 4.5" x 3.25"
Enclosure: Aluminum, fan-cooled, integrated dovetail clamps and
tripod strap
Power Input: 12V DC nominal, 13.8V DC max input voltage,
10A max input current, 5.5mm/2.1mm tip positive threaded
barrel connector
Power Output Port: 12V DC, 5.5mm/2.1mm tip positive barrel
connector, 7A max output current
Dew Heater Outputs: 2x RCA jacks, 12V DC, 7A max output
current for each port
Thermistor Jack: 2x 2.5mm Audio jack, compatible with Celestron
Dew Heater Rings and optional Celestron Thermistor
AUX Ports: 2x AUX ports, compatible with Celestron mounts and
other Celestron products
Environmental Sensor: Integrated, gives ambient temperature and
humidity data, can be recalibrated for best performance
Circuit protection: internally resettable fuses for each port,
reverse polarity protection, under-voltage, over-voltage, under-
current, over-current
Firmware: Upgradeable thorough Celestron Firmware Manager
(CFM) software
Power cable: 5.5mm/2.1mm threaded tip positive barrel connector
plug on one end, cigarette-lighter plug on the other end, 10A fuse,
16 gauge wire
10