When Installing
Make sure that unit is installed on a sound
structure that will support the full operating
weight of the cooler. See page 4.
Before attempting to hang the cooler in the
window, remove the louvers to reduce weight.
Do NOT connect power to cooler before
installation is complete.
MOUNTING
To install this cooler, the following tools are required:
• Adjustable wrenches
• Screwdrivers
• Electric drill
• 3/16" drill bit
• Level
1. Loosen the Adjustment Screw in the Stand-Off Bracket. Remove the Spacer-Rod
from the installation package and insert them into the Stand-Off brackets as shown.
2. Cut the Side Sealer Channels so that two of them will span the window when
butted together. Place two of the channels on the bottom duct flange as shown.
3. Place the Cooler in the center of the window with the bottom duct flange resting
against the sill.
4. Pull out the Spacer-Rods so as to allow the Rubber Feet to rest against the side of
the house. Tighten the Adjustment Screws.
5. Lower the window to rest on top of the duct behind the top duct flange.
6. Fasten a stop above the inside window sash to prevent the window from being
raised. Raising the window may cause the cooler to fall.
7. Adjust the Spacer-Rods to level the cooler. This will ensure proper water flow to the
pads.
8. Install the Chain Supports.
a. Drill pilot holes in the window frame, 3 feet above the top of the duct and the width
of the cooler apart. Install the Screw-Hooks in these pilot holes to the full depth of the
thread.
b. Hook one end of each Chain over each Screw-Hook.
c. Place S-Hooks in the in the holes at the top-rear of the cooler.
d. Place the opposite end of the S-Hooks in the free end of each Chain. Make sure
the chains are taut, but not so tight they pull the bottom of the cooler away from the
wall.
9. Install the Side Sealer Panels. These panels are the correct height, but need to be
trimmed to fit the width of your window. Trim the panels so that they reach from the
window frame to the side of the duct. Slide the panels in the channels you placed on
the bottom duct flange. Install the remaining Side-Sealer Channels over the top duct
flange and the Side-Sealer Panels.
All manuals and user guides at all-guides.com
SAFETY GUIDE LINES & CAUTIONS
When Operating
Make sure that circuit cooler is plugged into is
equipped with a (slow blow) breaker large
enough to support the full amperage of the
cooler.
To reduce the risk of fire or electrical shock, DO
NOT use this fan with any Solid-state speed
control device.
This cooler is equipped with an
thermally protected motor. If it shuts off on its
own for any reason,
warning
.
U U U U
2
Always Unplug the cooler before attempting
service of any kind.
Be sure to disconnect unit from power
source before servicing. If not, it can be
turned on from inside the house and start
unexpectedly.
a utomatic
If the motor shuts off because of thermal
U U U U
U U U U
overload,
i t can restart without
immediately.
U U U U
permanent damage will occur.
When Servicing
check
into
the
problem
If allowed to continue,

Publicidad