Priority; 100 V Line Speakers; Frame To Gnd Link - Optimus MAV-120Z6 Manual De Instalación Y Funcionamiento

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

MAV SERIES
AMPLIFIER
6.4. PRIORITY  
Unit has four priority levels. 
Priority 1 (max.): EMC input, activated by VOX control. It activates all zones. 
Priority 2: PMV‐6Z. It activates selected zones. 
Priority 3: MIC1, activated by VOX, it is broadcasted to front panel selected zones. 
Priority 4: MIC2 = MIC3 = MIC4 = LINE 5 = LINE6. 
6.5. 100 V LINE SPEAKERS 
Connect the speakers in parallel. The sum in W of all speakers connected to the amplifier must not 
exceed its power, 120 W for MAV‐120Z6, 240 W for MAV‐240Z6 and 500 W for MAV‐500Z6. 
 
 
NOTE: Each line is independent, never mix two lines. The minimum section is 1.5 mm², but it can be 
increased according to the installation requirements. 
6.6. FRAME TO GND LINK 
This amplifier includes a ground to frame link switch. A single frame to ground link should exist in 
the installation; in other case ground noise could appear. Place the switch in the GND position to 
join frame and ground or in the LIFT position to separate them. 
MAV SERIES Version 1.0
Page 9 of 13

Publicidad

Capítulos

Tabla de contenido
loading

Este manual también es adecuado para:

Mav-240z6Mav-500z6

Tabla de contenido