SINGLE PHASE WIRING DIAGRAM
To protect against fire and electrocution:
• DISCONNECT power BEFORE installing or servicing operator.
• Replace ONLY with fuse of same type and rating.
Fuse: 3AG, 3.2A, 120V, SLO-BLO
ON/OFF
SWITCH
L1
1 PHASE
POWER IN
L2
GROUND
R1
24VAC
R2
R3
RADIO
R4
SIGNAL
SAFETY ALARM
(100 db)
GL CONTROL BOARD
J2 PLUG
24VAC-IN
J2-3
24VAC-COMMON
J2-4
SOFT OPEN
J2-5
NC
J2-6
"B" LIMIT
J2-7
CONTACTOR B
J2-1
"A" LIMIT
J2-8
CONTACTOR A
J2-2
RPM - IN
J2-9
RPM - SUPPLY
J2-10
RPM GND
J2-11
J1 PLUG
RADIO COMMAND
J1-1
SHADOW
J1-2
+24VDC
J1-3
CLOSE
J1-4
STOP
J1-5
SOFT OPEN
J1-6
HARD OPEN
J1-7
INT. LOOP
J1-8
OBS. OPEN
J1-9
OBS. CLOSE
J1-10
24 VAC-COMMON
J1-11
DC-GND
J1-12
LOCK 1
J1-13
LOCK 1
J1-14
ALARM 1
J1-15
ALARM 1
J1-16
J4 PLUG
DUAL
GATE
= TERMINAL BLOCK IN LIMIT SWITCH ENCLOSURE (SL595 ONLY).
NOTES:
1. Transformer primary voltage same as operator line voltage 24V secondary 60VA.
2. Wire color: 115V black, 208V red, 230V orange.
3. Single phase units are equipped with an external line break device and may be equipped with an additional internal pilot duty thermal o/l device.
4. Outlet wiring: Black wire to brass screw, white wire to silver screw and green wire to green screw.
5. When using a remote control or Single Button Control Station in lieu of the Soft Open feature, perform the following modifications to the operator:
1. Remove the green wire from R4 of the radio block and mount the wire to terminal block TB1 position 6.
2. Move the brown wire on Terminal Block TB1 position 6 (from radio block R4) to Terminal Block TB1 position 1.
White
Black
GROUNDED
DUPLEX
OUTLET
(115V ONLY)
White
(SEE NOTE 2)
(S)
(S)
White
Black
Black
(B)
(B)
24V Sec.
Green
(SEE NOTE 1)
FUSE
(SEE NOTE 4)
3.2A
Black
AB
Blue
Blue
Yellow
Yellow/Black
Brown
Black
-
Red
+
Blue
Yellow
Green
3
L/S B
Purple
2
Purple
NC
COM
B
Yellow/
A1
L/S A
Black
Orange
1
NC COM
A
A1
White
Red
RPM
SENSOR
Black
OPEN
Yellow/
Black
Purple
Orange
Purple/White
Yellow/Black
Green
Yellow/
Yellow/Black
Black
STOP
RESET
Brown
Orange
Green
Gray
Orange/Black
Black
Black
Blue
Red
White
1
Red
2
White
B
4
3
White
115V ONLY
O/L
A
3
Black
4
White
White
208/230V
A
ONLY
2
1
B
6
5
Black
Black
MOTOR OVERLOAD
(SEE NOTE 3)
PRIMARY
Black (SL595 Orange)
115V ONLY
Yellow
(TB 2)
CD
(SEE NOTE 5)
A2
A2
CLOSE
Green
3
115V MOTOR
CONNECTION
A
5
6
Purple (SL595 Red)
4
B
1
2
Black
8
Yellow(SL595 White)
5
Gray (SL595 Green)
1
208V/230V MOTOR
CONNECTION
Purple (SL595 Red)
4
8
Blue
Yellow(SL595 White)
5
Gray (SL595 Green)
1
TO REVERSE MOTOR
DIRECTION INTERCHANGE
PURPLE & GRAY WIRES
ON MODEL SL585
OR THE RED & GREEN WIRES
ON MODEL SL595
4
Green
6
White
FREE EXIT
7
Red
LOOP HARNESS
8
Black
10 PIN - 1,2,3,5
9
Brown
10
Gray
4
Green
6
White
INTERRUPT (SAFETY)
LOOP HARNESS
7
Red
10 PIN - 1,2,3,5
8
Black
9
Brown
10
Gray
TB 1
Purple
1
White
Purple/White
2
Yellow/Black
3
Green
4
Yellow/Black
5
White
Brown
6
7
Orange
8
Green
Gray
9
Orange/Black
10
White
11
Red
12
Black
13
Black
14
Blue
15
Yellow
16
Gray
17
Brown
18
Gray
19
Brown
20
(SEE NOTE 3)
2
Black/Blue
Black
115V BRAKE
Black
SOLENOID
3
Black/Blue
(SEE NOTE 3)
Black/Blue
3
Black
230V BRAKE
2
Black
SOLENOID
Black/Blue
INTERNAL MOTOR
WIRING
1 - BLUE
2 - WHITE
3 - ORANGE
4 - YELLOW
5 - BLACK
8 - RED
O/L - BROWN
CAPPED
CAPPED
FIELD CONNECTIONS
RADIO
SHADOW
VDC COM
CLOSE
STOP/COM
SOFT OPEN
HARD OPEN
INTERRUPT (SAFETY)
OPEN
EDGE/PHOTOEYE (SAFETY)
CLOSE
MASTER / SECOND
MAGLOCK
24 VAC
INTERRUPT LOOP (SAFETY)
EXIT LOOP