Mechanical
Process Connections
• threaded connection
•
• flanged connection
• Tri-clamp
Enclosure
• construction
• conduit entry
• ingress protection
• vane and shaft construction
Weight
Standard temperature:
• compact
• extended
• angled extended
• cable
High temperature:
• compact
• extended
• angled extended
• cable
Environmental
• location
• altitude
• ambient temperature
• relative humidity
• Installation category
• Pollution degree
With the heated enclosure option, the ambient temperature rating improves to
Note:
–40 to +60 °C (–40 to +140 °F).
Page EN-4
SITRANS LPS200 – OPERATING INSTRUCTIONS
All manuals and user guides at all-guides.com
1", 1¼" , 1½" NPT or 1", 1¼" , 1½" BSP
material: stainless steel 303 (1.4305) or 316L
(1.4404), optional aluminum
DN 32 PN 6, DN 100 PN 6, DN 100 PN 16,
2", 3", 4" ASME, 150 lb, B 16.5 (1.4541/321)
2" DN50 ISO 2852
epoxy coated aluminum
2 x M20 x 1.5, or
2 x ½" NPT
Type 4X/NEMA 4X/IP66
stainless steel 304 and 303 (1.4301 and 1.4305)
or 316L (1.4404)
1.8 kg (4.0 lb)
2.2 kg (4.9 lb)
4.0 kg (8.8 lb)
3.2 kg (7. 1 lb)
2.6 kg (5.7 lb)
3.0 kg (6.6 lb)
5.2 kg (11.4 lb)
4.0 kg (8.8 lb)
indoor/outdoor
max. 2000 m (6562 ft)
–25 to +60 °C (–13 to +140 °F)
0 to 100 %, suitable for outdoor (ingress
protection: Type 4X/NEMA 4X/IP66)
III
2
7ML19985FS62