Installing The Dockside Discharge Fitting; Connecting The Water Supply - Dometic GROUP M65-700 Instrucciones De Funcionamiento

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 32
Gravity-discharge Toilet
2. Run a 5/8 in. (16 mm) I.D. marine sanitation quality
hose from the thru-hull vent fitting to the vent fitting
on the holding tank.
3. Secure the hose to the vent fittings with two stainless
steel band clamps at each connection.
6 .3 Installing the Dockside
Discharge Fitting
NOTICE: The holding tank on the toilet is designed to
withstand discharge by a properly operating discharge
pump.
1. Install the dockside discharge fitting according to the
manufacturer's instructions.
I
The dockside discharge fitting should be
located in the deck directly above the toilet.
2. Run a 1.5 in. (38 mm) I.D. marine sanitation quality
hose from the dockside discharge fitting to the
pumpout fitting.
3. Secure the hose to the fittings with two stainless steel
band clamps at each connection.

6 .4 Connecting the Water Supply

q
6 Removing the Pedal Cover
Pedal Cover
q
Back Plate
w
1. Remove the two screws from the rear of the pedal
cover.
EN
e
w
Screws
e
2. Pull off the pedal cover.
q
7 Water Supply Connections
Water Supply Line
q
3. Attach the water supply line to the inlet fitting.
4. Turn on the water supply and flush several times to
check for leaks.
5. Replace the pedal cover.
6. Replace the back plate and secure with the screws.
Installation
w
Inlet Fitting
w
7

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

M65-50009610003317312070001

Tabla de contenido