Connection.
Isolated battery systems must be limited to less than ± 47V above ground under fault conditions.
The inverter is adequately protected by internal fuses, but for protection of input cabling, a 100A fuse to DIN 43560/1
may be fitted in the battery positive lead. Fuse the switch wire at 1A. These fuses are only necessary if there is danger
of insulation damage to the wiring after it leaves the battery.
Fixing: Mount the inverter near the battery. There are four 3.5mm fixing holes, positioned 70mm by 233mm.
FUSE REPLACEMENT: Disconnect the unit completely from the battery then wait ten minutes. Remove the cover
and replace the fuses. 12V models use 3 x 30A. 24V models use 3 x 15A. Fit the cover and connect the battery.
SPECIFICATION:
Input Voltage, continuous:
Input Voltage, 10 seconds:
Input Current per 10W loading (nominal):
Input Current, No Load (typical):
Battery Low Warning:
Battery Low Latch Off:
AC Output Voltage:
Output Power, Continuous:
Output Power, Short term:
Output Power, Surge:
Isolation, input to ground:
Ambient Temperature range:
Size and Weight:
Manufacturer:
SUPPORT:
Because of the specialist nature of these units, all questions should be directed to SMET Ltd. on +44
(0)118 983 1222. We welcome queries to ensure your safety.
Ensure that the battery voltage is correct for the model. Do not reverse the polarity of the input voltage. Use at least
12mm 2 wire to connect the converter to the battery. Thin wire will cause fire hazard. Fuse Battery at source. Fuse
switch wire at 1A. Only operate the unit from a battery. Do not connect the unit to any other power source. Do not use
with capacitive loads greater than 2.0uF. Power factor correction capacitors must be removed from fluorescent light
fittings. For inside use only. Do not expose to moisture. Do not cover. The unit will run hot when under elevated
load. Disconnect the battery before changing the fuse. Do not operate the unit with the cover off. When using tools
outside, ground fault interrupter (RCD) protection must be used. Turn off when not in use to avoid battery drain. This
equipment is supplied on the basis of the user determining the suitability of use. Not to be used for life support. Do not
use in a moving vehicle without the vehicle manufacturer's consent. Do not use for marine or aviation applications
without our written agreement. We reserve the right to change the specification without notice.
Information: +44 (0)118 983 1222
___________________________________________________________________________________________________________________________________________
SMET Limited.
Registered in England & Wales, Number 6760677.
All manuals and user guides at all-guides.com
Pos
+
Switch
Battery
_
Neg
230V RMS 50Hz typical, 215V to 245V depending on load power
and input voltage. Maximum Load Capacitance 2.0uF.
700 Watts (resistance load).
800 Watts (resistance load), for five minutes.
1000 Watts (resistance load), for 500 mS.
500Kohm minimum at ± 100V maximum.
-40C to +35C operating, -40C to +70C storage.
260mm by 103mm by 64mm. Weight: 1.55Kg.
SMET Ltd., Reading, Berks., RG7 3BL, UK.
SAFETY WARNING.
International Section Follows.
Registered .Office: Bell House, Ashford Hill Road, Ashford Hill, Berks. RG19 8BB.
+ I/P
Output
on/off
Socket
- I/P
12V INPUT.
24V INPUT.
11V - 15V
22V - 32V
10V - 18V
20V - 38V
1 A
0.5A
0.5A
0.35A
10.5V
20.7V
9.6V
19V
Web: http://www.custompsudesign.com.
Ground.
36V INPUT.
32V - 42V
30V - 48V
0.33A
0.25A
32V
29V
VAT No. (GB) 944 0645 24