RECYCLING VERSION AIR OUTLET
To install the hood in recycling version, the optional charcoal
filter kit must be purchased.
• Remove the chimney angle bracket.
• Screw the filter cover onto the air outlet, using four screws 12c
(2.9 x 12.5).
• Fix the air outlet grid 8 on the recirculation air outlet using the
2 screws 12d (2,9 x 9,5) provided.
Fitting the Lighting Unit
• Insert the Lighting unit cable into the opening.
• Rest the Lighting unit 9 .
• Fix it using the Screws 12r provided.
• Remove grease filters.
• Inside the hood canopy there is a wiring box for connection of
the lighting unit.
• Open the box and connect the wires to the terminal inside it,
checking that the colours are combined properly.
• Close the wiring box, replace the grease filters and close the
doors.
EN
12d
8
12c
16
12r
1
10
0