en
Instruction
ADM-I12W1 motion detector
The detector detects movement in the
room under surveillance
7
and initiates
an alarm. It responds most sensitively to
movement in the directions indicated by
arrows
7
B / D. The alarm is transferred
by wireless. The back tamper recognizes
if the detector is removed with force.
Prerequisites
The detector should be installed by peo-
ple with specialist knowledge and in
compliance with valid regulations.
The detector is only intended
for indoor use. Note the posi-
tioning instructions
Opening the detector
1. Check the scope of delivery
2. Slide up the screw-on cover
loosen the screw
2
B.
3. Pull the housing front
2
D off the base
2
C.
Fitting the detector
1. Fit the mounting base
2
C as follows:
- Define type of fastening
4
A / B. (also
refer to mounting bracket option)
- Break open three fixing holes.
- Fit mounting base at the proposed
height.
The mounting base should be
secured using two screws
A / B and the back tamper
4
with one screw
4
C.
2. Pull out insulation strip between bat-
tery and bracket
8
A.
3. Press the tamper contact
5
ter the detector with the system.
For safety reasons only use
the battery supplied and not
any other type.
4. Fold front
2
D back onto mounting
base
2
C and secure with screw
Slide down screw-on cover
Programming
To adjust the settings to the application,
move the switches into the corresponding
positions:
PIR sensitivity
5
B
Low sensitivity, for busy envi-
ronments.
All manuals and user guides at all-guides.com
High sensitivity, for quiet
environments.*
* factory setting
Pet immunity
5
PET
Suppresses alarm for pets
up to a weight of 12 kg.*
12kg
Suppresses alarm for pets
up to a weight of 30 kg.
* factory setting
Sensitivity setting
-
+
*
Turn potentiometer
6
.
the position required to
adjust detector to room size
and field of vision.
1
.
* factory center is the middle position
2
A and
(12-meter field of vision)
ID registration
You will find instructions for integrating
the detector in the control panel in the
control panel's installation manual.
Walk test
1. Call up walk test mode in the control
panel.
2. Hold a magnet to the right of the de-
tector for 1 second
3. Run the walk test for alarm triggering
in the whole detection area
detector.
Alarm transmission test
1. Call up walk test mode in the control
panel.
2. Hold a magnet to the right of the de-
B to regis-
tector for at least 2 seconds
3. The alarm transmission test has now
started. 11 test signals are sent to the
control panel at an interval of 6 sec-
onds (the LED
transmission).
2
B.
4. The test is passed if the control panel
receives the test signals and indicates
2
A.
this accordingly.
Options
Narrow angle lens kit AO-C25
The kit enables the detection area cov-
erage to be defined to a narrow angle as
shown in
7
D.
Loosen the lens currently at the positions
shown in
5
F and remove from the de-
tector. Insert adapter
and press down narrow angle lens.
White light filter AO-WL10k
The white light filter is needed for applica-
tions with extreme white light interference
(> 4000 lux).
Loosen the lens currently at position
and remove this from the detector. Insert
A
adapter
lens back down.
Wall & ceiling mounting brackets
The mounting brackets AZ-MBG2
(ceiling
be used to swivel the detector ± 45°.
D
5
Technical data
5
D into
Detection area
coverage
wide angle
Detection area
coverage
narrow angle
Range of wireless
module
Frequency:
ADM-I12W1
ADM-I12W2
Identification
Data protocol
Event transmission
8
B.
Test mode
7
of the
Battery power sav-
ing
Battery
8
B.
Warm up period
Pet immunity
10
flashes during each
EMI rejection up to
2 GHz
Operating tempera-
ture
Storage tempera-
ture
Air humidity
EN 60721
Type of housing
protection
EN 60529,
EN 50102
3
C in to detector
- 3 -
3
B in to detector and press the
9
9
B and wall
9
C mounting) can
12 m
7
B
20 m
7
D
Up to 300 m out-
doors
868 MHz
916 MHz
ID serial number
24 bits
SiWay
Alarm, sabotage,
surveillance, bat-
tery low
Walk test & alarm
transmission test
Automatic energy
saving function
Lithium 3 V
Type: xx123
Size: 2/3 AA
Capacity:
1550mAh
60 ± 5 s
< 12 kg
< 30 kg
> 10 V/m
-10 °C ... +50°C
-20 °C ... +60 °C
< 85 %rF, not
condensing
IP41 / IK02
en
5
F
9