Technical Parameters - 2N LiftIP Manual Del Usuario

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 10
Connection via Voice Alarm Station
You can connect the IO extender via a VAS (Voice Alarm
Station) too. Connect the VAS to the Extender connector
(refer to Subs. 2.7 of the VAS Manual).
Connect the IO extender to the VAS switch. Put the
connector on the Alarm IN/Program jumper (see Fig.).
• Disconnect LiftIP from the power supply (DC 10–30 V or PoE) while mounting the IO extender.
• Make sure that all the pins are put properly in the connector while mounting the IO extender.
• Keep the correct connector wiring (yellow wire – see Fig.).
• A wrong wiring may lead to the module damage.

Technical Parameters

Input
Input type
• Never connect any voltage sources to the input; only an N/O contact disconnected from any
other circuit may be connected to the input.
Outputs
Maximum load
Insulation strength
Output type
3
Contact controlled, galvanically non-isolated
60 V / 500 mA
500V
open at relax, galvanically isolated, can switch both voltage
polarities

Publicidad

Tabla de contenido
loading