Important Hints on Installation:
• You should never install the pump by suspending it unsupported from its delivery pipe or
power cable.
• The submersible motor pump must be suspended from the specially provided handle or
be placed on the bottom of the shaft.
• To guarantee that the pump works properly, the bottom of the shaft must be kept free of
sludge and dirt of all kinds.
• If the level of water sinks too far, any sludge in the shaft will dry out quickly and stop the
pump from starting up. It is necessary, therefore, to check the submersible motor pump
regularly (by carrying out start-up tests).
• The floater is adjusted in a way that the pump can immediately be started.
NOTE: The pump shaft should have minimum dimensions of 40x40X50cm, so that the floa-
ting switch can move freely.
3. Mains Supply
• Your new submersible pump is equipped with a shockproof plug according to regulations.
The pump is designed to be connected to a 230 V~, 50Hz safety socket.
• Make sure that the socket is sufficiently secured (min. 6 Amp.) and is in excellent condi-
tion. Introduce the plug into the socket and the pump is ready to go.
• If the mains cable or plug suffers any damage from external action, repairs to the cable
are prohibited.
NOTE: This work may only be performed by a qualified electrician or customer service.
4. Areas of Use
• This pump is used primarily as cellar pump. When installed in a shaft, this pump provides
protection from flooding.
• They are also used wherever water has to be moved from one place to another, e.g. in the
home, agriculture, horticulture, plumbing and many other applications.
10
All manuals and user guides at all-guides.com