Technical Data

Battery Charger
Article number
Output voltage
V
Charging current
Allowable charging tem-
perature range
°C
Charging time for battery
capacity, approx.
– 1.0 Ah
min
– 1.3 Ah
min
Number of battery cells
Weight according to
EPTA-Procedure 01/2003
kg
Protection class
Please observe the article number on the type plate of
your battery charger. The trade names of individual bat-
tery chargers may vary.
Operation

Starting Operation

Observe the mains voltage! The voltage of
the power supply must correspond with the
data given on the nameplate of the battery
charger. Battery chargers marked with 230 V
can also be operated with 220 V.
Charging Procedure
The charging procedure starts as soon as the
mains plug of the battery charger is plugged into
the socket outlet and the battery 1 is inserted in-
to the charging compartment 2.
Due to the intelligent charging method, the
charging condition of the battery is automatical-
ly detected and the battery is charged with the
optimum charging current, depending on bat-
tery temperature and voltage.
This gives longer life to the battery and always
leaves it fully charged when kept in the charger
for storage.
Bosch Power Tools
Meaning of the Indication Elements
Flashing Green Battery Charge Indicator 4
AL 1130 CV
Professional
2 607 225 1..
10.8
Note: The rapid-charging procedure is only pos-
A
3.0
sible when the battery temperature is within the
allowable charging temperature range, see sec-
tion "Technical Data".
0 – 45
Continuous Lighting of the Green Battery
Charge Indicator 4
30
30
3
0.5
Afterwards, the battery can be removed for im-
mediate use.
/ II
When the battery is not inserted, continuous
lighting of the battery charge indicator 4 indi-
cates that the mains plug is inserted in the sock-
et and that the battery charger is ready for oper-
ation.
Continuous Lighting of the Red Battery Charge
Indicator 3
charging temperature range, see section "Tech-
nical Data". As soon as the allowable charging
temperature range is reached, the battery
charger automatically switches to rapid charg-
ing.
Flashing Red Battery Charge Indicator 3

English | 9

The rapid-charging procedure is
signalled by a flashing green bat-
tery charge indicator 4.
Continuous lighting of the green
battery charge indicator 4 indi-
cates that the battery is fully
charged.
Continuous lighting of the red
battery charge indicator 3 indi-
cates that the temperature of the
battery is not within the allowable
A flashing red battery charge indi-
cator 3 indicates a different mal-
function of the charging proce-
dure, see section
"Troubleshooting – Causes and
Corrective Measures".