10.9
NSF performance data
NSF Performance Data for the HYPRO WATER Filter System
Model
Replacement
HYPRO Water 201001
This system has been tested according to NSF/ANSI 42, 53 and 401 for the
reduction of the substances listed below. The concentration of the indicated
substances in water entering the system was reduced to a concentration less
than or equal to the permissible limit for water leaving the system, as specified
in NSF/ANSI 42, 53 and 401.
Substance
Chlorine Taste and
Odor (mg/L as chlorine)
Atrazine (µg/L)
NSF/ANSI 401 Emerging compounds/Incidental Contaminants
Bisphenol A (ng/L)
Estrone (ng/L)
Ibuprofen (ng/L)
Naproxen (ng/L)
Nonylphenol (ng/L)
Phenytoin (ng/L)
50
Rated
capacity
2,000 l
HYTECON AG, Brunnhalde 10, 6006 Luzern, Switzerland
Influent Challenge
Concentration
NSF/ANSI 42 Aesthetic Effects
2.0 ± 10 %
NSF/ANSI 53 Health Effects
9.0 ± 10%
2,000 ± 20%
140 ± 20%
400 ± 20%
140 ± 20%
1,400 ± 20%
200 ± 20%
Operating
Water
pressure
temperature
4 bar/0.4 MPa 5° C - 30° C
Reduction Requirements/
Max. Permissible Product
Water Concentration
≥ 50 %
3.0
300
20
60
20
200
30
Flow rate
2.87 l/min
% Reduction
> 97
> 94
> 99
> 96
> 95
> 96
> 96
> 95
HYPRO WATER – 01/2022