Warmup 6iE-XX-YY-ZZ Manual Del Usuario página 2

Publicidad

1
2
5
6
7
Wed 15 Feb
12:38PM
21.5
Language
°C
English
22.0 until
22.2
12:45pm
Table 1.0 / Tableau / Tabla 1.0
Use Case
Control
#
Cas d'utilisation
Contrôle
Caso de uso
Control
A1
B1
C3
1
P1 & PC
A3
B2
C1
2
*
P1 & PC
3
A1
B2
C2
P1 & PC
A2
B1
C3
4
A1
B1
C1
5
**
Thermostat in room
Thermostat out of room
A1
A2
Termostato en la habitación
Termostato fuera de la habitación
Thermostat dans la pièce
Thermostat hors de la pièce
Air temperature schedule
Floor temperature schedule
B1
B2
Temperatura del aire programación
Programa de temperatura del suelo
Programme de température de l'air
Programme de température du sol
Floor limit
Air limit
C1
C2
Límite del suelo
Límite de aire
Limite de sol
Limite de air
Internal air sensor
Floor sensor
Sensor de aire interno
Sensor de suelo
Sonde d'air interne
Sonde de sol
2
Recommended when thermostat is
5
Recommended when thermostat is
*
**
out of the heated room
in the heated room
Recommandé lorsque le thermostat
Recommandé lorsque le thermostat
Recomendado cuando el termostato
Recomendado cuando el termostato
está fuera de la habitación
está en la habitación climatizada
climatizada
Warmup - IM - 6iE - V1.3 2021-06-17_NA-ML.indd 2
3
4ft
(1.2m)
8
'MyHeating'
by Warmup
Wed 15 Feb
12:38PM
21.5
°C
22.0 until
22.2
12:45pm
Limit Sensor
Sonde de limitation
Sensor de límite
X
X
X
P2 & PC
Thermostat in/out of room
A3
Termostato dentro / fuera de la habitación
Thermostat dans/hors de la pièce
C3
Sin límite de suelo
Pas de limite de sol
Air sensor
Sensor de aire
Sonde d'air
4
9
EN
1.
Isolate the 6iE and supply from the mains supply.
2.
Unclip the display from the power base and remove
the display
3.
DO NOT install the 6iE near a window/door, in direct
sunlight or above another heat generating device (e.g.
radiator or TV).
4.
Ensure distance from the router to 6iE is not
excessive to reduce range or interference issues.
5.
Install a 3-1/2" (89 mm) deep single gang or 2-gang
box with mud ring in your preferred thermostat
location. Pull wires (heater, supply and sensor) through
gang box and complete terminal wiring.
screws through mounting holes of the power base and
tighten.
in accordance with National Electrical Code.
WIRING CONNECTIONS
LOAD L1 & L2
Heater Load Max.15A
(1800W/120V, 3600W/240V)
LINE L1
Supply Live (120 V)
LINE L2
Supply Neutral (120 V) /
Supply Live (240 V)
P1 & PC
Probe 1 -
Floor/Air Control Sensor
(No Polarity)
P2 & PC
Probe 2 -
Limit Sensor (No Polarity)
Please see Table 1.0 for thermostat use cases.
NOTE:
The function of Probe 1, Probe 2 from Control/
Limit Sensor can be swapped in Advanced Settings;
Sensors & Application.
6.
Re-attach the display to the power base and switch
on the 6iE. Follow the on screen instructions to set up
the system. Once set up a QR Code will appear.
7.
Download the MyHeating App.
8.
Open the MyHeating App and scan the QR Code on
the 6iE screen and follow the instructions in the App to
complete setup.
9.
Scan the QR Code for full online user guide.
Model
6iE-XX-YY-ZZ
Voltage
110V - 240V AC +/-15% 50Hz/60Hz
Protection
II
15A resistive (120 V/1800W,
Max. Load
240 V 3600W)
GFCI
Class A GFCI with 5mA trip level
Rated impulse voltage
4000V
Automatic action
100,000
Disconnection means
1B
Pollution degree
2
Max. Ambient
40°C / 104°F (T40)
Temperature
Relative Humidity
80 %
IP Rating
IP30
Sensors
Floor/Air
Sensor Type
NTC10K @ 25°C
Operating Frequency
2412 - 2462MHz
Max. Radio-Frequency
20dBm
Power Transmitted
Compatibility
UL-60730-1
UL-60730-2-9
UL-943
Standards
CAN/CSA-E60730-1
CAN/CSA-E60730-2-9
CAN/CSA-C22.2 No. 144.1
FCC 47 CFR Part 15, ICES-003