Threaded connections require application of a quality grade thread sealant to seal the joint assembly.
WARNING: SOME PIPE JOINT COMPOUNDS OR TEFLON
SUBSTANCES THAT COULD CAUSE STRESS CRACKING TO PLASTIC. TRANSITIONS
TO METAL PIPE REQUIRE THOROUGH CLEANING AND DEGREASING TO REMOVE ANY
PIPE THREAD CUTTING OILS.
Spears
thread sealant that has been tested for compatibility with Spears
Wrench Flats
NOT FOR USE WITH COMPRESSED AIR OR GAS
WARNING: DO NOT USE COMPRESSED AIR OR GAS TO TEST ANY PVC OR CPVC THERMOPLASTIC
PIPING PRODUCT OR SYSTEM, AND DO NOT USE DEVICES PROPELLED BY COMPRESSED AIR
OR GAS TO CLEAR SYSTEMS. THESE PRACTICES MAY RESULT IN EXPLOSIVE FRAGMENTATION
OF SYSTEM PIPING AND COMPONENTS CAUSING BODILY INJURY OR DEATH.
SPEARS
15853 Olden St., Sylmar, CA 91342 • PO Box 9203, Sylmar, CA 91392
© Copyright 2009 Spears
Manufacturing Company
®
All Rights Reserved. Printed in the United States of America 10/09
THREADED CONNECTIONS
Manufacturing Company highly recommends the use of Spears
®
Apply Thread Sealant to
male pipe threads only.
Typical fl ex
connector
For connection to
fl exible connector
with gasket
PRECAUTIONS AND WARNINGS
MANUFACTURING COMPANY • CORPORATE OFFICE
®
(818) 364-1611 • www.spearsmfg.com
®
PASTES MAY CONTAIN
®
Assemble Joint Hand Tight
Finish tightening with
fl at-faced wrench
Do not use pipe wrenches Flats
on the valve. Apply wrench make-
up no more than one to two
turns beyond hand tight. Care
must be taken in fi nal positioning
so as to avoid the need to "back-
up" the wrenched assembly.