All manuals and user guides at all-guides.com
1. DISpLAy 3 ½ digit, 7 segment, 15mm high LCD.
2. fUNCTION AND RANGE SwITCh This switch is used to
select the function and desired range as well as to turn on the
instrument. To extend the life of its battery, the switch should be
in the OFF position when the instrument is not in use.
3. 'hOLD'-bUTTON by pressing this button the screen will retain
the last reading and the symbol H appear in the LCD until you
next press the button.
4. 10A jACk Plug in connector for red (positive) test lead for 10A
measurements.
5. COMMON jACk Plug in connector for black (negative) test lead.
6. VΩMA jACk Plug in connector for red (positive) test lead for all
voltage and resistance and current (except 10A) measurements.
SpECIfICATIONS
Accuracies are guaranteed for 1 year, 23˚C ± 5˚C, less than 80% RH.
DC VOLTAGE
Range
200µV
2V
20V
200V
600V
Overload protection: 250 V rms for level of 200 µV, and 600V DC
or rms AC for other levels.
Resolution
100µV
1mV
10mV
100mV
1V
Accuracy
±0.5% of rdg ±3D
±0.5% of rdg ±3D
±0.5% of rdg ±3D
±0.5% of rdg ±3D
±0.8% of rdg ±5D