Descargar Imprimir esta página
LiftMaster FBSL3000 Manual Del Usuario
LiftMaster FBSL3000 Manual Del Usuario

LiftMaster FBSL3000 Manual Del Usuario

Instrucciones para armar

Publicidad

Idiomas disponibles

Idiomas disponibles

Enlaces rápidos

CARTON INVENTORY
8-32 x 3/16"
Cable Bracket
Handle
Set Screw
Fire Access Box
INSTALLATION
INSTALL THE CABLE IN THE OPERATOR
1. Install steel conduit from the operator base to the fi re access
box mounting location. The mounting location should be
outside the gate perimeter approximately 4-1/2 feet (1.4 m)
high.
2. Run the ball end of the fi re access box cable inside the conduit
and into the operator.
3. Insert the ball end through the bracket and thread the nut onto
the cable.
4. Insert the ball end through the keyhole slot and secure with
the push plug as shown.
5. Fasten the threaded cable end to the bracket with the nut.
6. Secure the fi re access box cable in the operator with cable ties
or stick on wire clips.
8-32 x 1/2"
Screws (2)
Screw (1)
Wire Clips
Cable Collar
Set Screw
Connector
Cable Ties (4)
Cable Stop
Push Plug
Nut
Cable
FOR SL3000501U & SL3000101U GATE OPERATORS
To avoid SERIOUS PERSONAL INJURY or DEATH from
electrocution:
• Disconnect electric power to operator BEFORE installing fire
access box.
• Fire access box to be mounted based on local fire codes.
Review local fire codes BEFORE proceeding with installation
of fire access box.
Stick On
Wire Clip
Conduit
FIRE ACCESS BOX
MODEL FBSL3000
Push Plug
Keyhole
Slot
Nut
Bracket
Cable

Publicidad

loading

Resumen de contenidos para LiftMaster FBSL3000

  • Página 1 FIRE ACCESS BOX MODEL FBSL3000 FOR SL3000501U & SL3000101U GATE OPERATORS CARTON INVENTORY 8-32 x 1/2" Screws (2) To avoid SERIOUS PERSONAL INJURY or DEATH from 8-32 x 3/16" electrocution: Screw (1) Wire Clips • Disconnect electric power to operator BEFORE installing fire access box.
  • Página 2 INSTALLATION INSTALL THE FIRE ACCESS BOX FIGURE 1: 1. Insert the connector into the back of fi re access box and secure with the nut. 2. Insert the conduit and cable through the connector and into the fi re access box. 3.
  • Página 3 BOÎTIER D’ACCÈS DU SERVICE DES INCENDIES MODÈLE FBSL3000 POUR ACTIONNEURS DE BARRIÈRE SL3000501U ET SL3000101U INVENTAIRE DE L’EMBALLAGE Vis 8-32 x 1/2 po (2) Pour prévenir d’éventuelles BLESSURES GRAVES, voire Vis 8-32 x MORTELLES suite à une décharge électrique :...
  • Página 4 INSTALLATION INSTALLATION DU BOÎTIER D’ACCÈS DU SERVICE DES INCENDIES FIGURE 1: 1. Insérer le connecteur à l’arrière du boîtier d’accès du service des incendies et le fi xer avec l’écrou. 2. Insérer la conduite et le câble par le connecteur et dans le boîtier d’accès du service des incendies.
  • Página 5 CAJA DE ACCESO PARA INCENDIOS MODELO FBSL3000 PARA OPERADORES DE LAS COMPUERTAS SL3000501U Y SL3000101U CONTENIDO DE LA CAJA Tornillos 8-32 x 1/2" (2) Para evitar una LESIÓN PERSONAL GRAVE o INCLUSO LA Tornillo 8-32 x MUERTE por electrocución: 3/16" (1) Pasadores del cable •...
  • Página 6 INSTALACIÓN INSTALAR LA CAJA DE ACCESO PARA INCENDIOS FIGURA 1: 1. Inserte el conector en la parte trasera de la caja de acceso para incendios y asegúrelo con la tuerca. 2. Inserte el conducto y el cable a través del conector y dentro de la caja de acceso para incendios.
  • Página 8 © 2016, LiftMaster All Rights Reserved Tous droits réservés 01-37859 Todos los derechos reservados...