Operation
Resetting Your Inverter to Restore AC Power
Your Inverter may cease supplying AC power in order to protect itself from overload or to protect your electrical system. To
restore normal functioning:
Low Battery Shutdown Reset: Set operating mode switch to "OFF" and run vehicle engine to recharge battery. When
battery is adequately charged, switch operating mode switch back to either "REMOTE" or "ON."
Overload Shutdown Reset: Set operating mode switch to "OFF" and remove some of the connected electrical load (ie:
turn off some of the AC devices drawing power which may have caused the overload of the unit). Wait one minute, then
switch operating mode switch back to either "REMOTE" or "ON."
Output Circuit Breaker Reset (Select Models): Alternatively, check output circuit breaker(s) on the unit's front panel. If
tripped, remove some of the electrical load, then wait one minute to allow components to cool before resetting the circuit
breaker. See Troubleshooting for other possible reasons AC output may be absent.
Set Battery Charge Conserver (Load Sense) Dial
In order to save battery power, the Inverter automatically shuts off in the absence of any power demand
from connected equipment or appliances (the electrical load). When the unit detects a load, it automatically
turns on. Users may choose the minimum load the Inverter will detect by adjusting the Battery Charge
Conserver Dial (see diagram). Using a small tool, turn the dial clockwise to lower the minimum load that will
be detected, causing the Inverter to turn on for smaller loads. When the dial is turned fully clockwise, the
Inverter will operate even when there is no load. Turn the dial counterclockwise to set a higher minimum load, causing the
Inverter to stay off until the new minimum load is reached. When the dial is turned fully counterclockwise, the Inverter will
turn on when it detects any load greater than approximately 150 Watts.
Note: The factory setting for the dial is fully clockwise. However, based on the threshold load to which you'd like the Inverter to
respond, you should adjust the dial counterclockwise to reduce its sensitivity until the Inverter is active only when connected
equipment or appliances are actually in use.
Connect Remote Control—OPTIONAL
All models feature an 8-conductor telephone style receptacle on the front panel for use with an optional remote control
module (Tripp Lite model APSRM4, sold separately or included with PV3000HF models). The remote module allows
the Inverter to be mounted in a compartment or cabinet out of sight, while operated conveniently from your vehicle's
dashboard. See instructions packed with the remote control module.