12.3 Emptying the condensate container
WARNING!
The condensate is not of drinking water quality and can cause poisoning if consumed.
•
Do not drink the condensate!
NOTICE!
Water flowing out of the air conditioner can damage floors and furniture.
•
Empty the condensate container in a suitable place (e�g� over a drain)�
•
Make sure that the outlets for condensate are properly closed�
Condensate is produced in the operating modes cooling and dehumidification. A large part of the con-
densate is discharged to the outside via the exhaust air� The remaining condensate collects in a con-
tainer inside the unit. If the error code „E4" appears in the status display (c), the condensate container
must be emptied�
Proceed as follows to empty the condensate container:
1� Switch off the air conditioner and disconnect the mains cable from the socket at the plug�
2� Transport the air conditioner to a suitable place and take a collection container�
The collection container should be able to hold approx. 1.1 l.
3� Hold the collection container under the upper condensate outlet (8)�
4� Open the upper condensate outlet and allow the condensate to drain into the collection container�
5� Close the upper condensate outlet with the plug�
6� Empty the collection container�
7� Hold the collection container under the lower condensate outlet (10)�
7�1 Alternatively, you can position the air conditioner above a floor drain.
8� Open the lower condensate outlet and allow the condensate to drain into the collection container
or into a floor drain.
9� Close the lower condensate outlet with the plug�
The condensate container is now empy. The error code in the status display is no longer shown.
13
Storage
DANGER!
The air conditioner contains propane (R290) as a refrigerant. Propane in combination with air is highly
combustible and can lead to an explosion.
•
Only operate and store the air conditioner in rooms with an area of 10 m² to avoid the danger of a
concentration of flammable gas building up in the air.
•
Do not operate the air conditioner in rooms where there are sources of ignition (e.g. naked fla-
mes, electric heaters, gas appliances that are switched on)�
CAUTION!
Moisture in the air conditioner can lead to deposits and mould.
•
If you do not use the air conditioner for the next seven days, store it according to the following
instructions�
Perform the following operations before storing the air conditioner:
1� Empty the condensation tank (see chapter 12�4)�
2� Clean the air filter (see chapter 12.3).
3� Leave the air conditioner running in ventilation mode for 5 to 6 hours in a dry room to allow the in-
side of the air conditioner to dry�
4� Remove the batteries from the remote control�
5� Store the air conditioner in a suitable place� In particular, observe the instructions in the section
„Operation and storage conditions" in chapter 1.
Risk of poisoning!
Material damage!
Fire hazard!
Irritation of the respiratory tract!
EN