5.0
MAINTENANCE
Fig. 6
5.3 LUBRICATION
The pressure washer is designed with a permanent lubrication
system. Conventional oil check and oil changes are not
necessary.
NOTE: IN CASE OF OIL LEAKAGE, CONTACT THE
CUSTOMER SERVICE DEPARTMENT CONCERNING
REPAIR. A SMALL AMOUNT OF LEAKAGE IS NORMAL.
5.4 WATER SCREEN
The pressure washer is equipped with a water inlet screen to
protect the pump.
CAUTION: if the screen is not kept clean, the flow of
water to the pressure washer will be restricted and
the pump may be damaged.
•
To clean inner conical water screen, remove quick
connect and remove the plastic screen from the pump
inlet.
•
Backflush screen to clean.
•
Replace screen and quick connect immediately to
prevent any foreign matter from entering the pump.
CAUTION: do not damage the screen while
removing or cleaning. Any foreign particles entering
the pump may damage the pump.
5.5 COOLING SYSTEM
The air vents, located in and around the pressure washer,
must be kept clean and free of any obstructions to ensure
proper air cooling of the motor during operation.
WARNING: prevent water from penetrating the
vents of the pressure washer to minimize the risk of
damage to the machine and to reduce the risk of
shock to the operator.
6.0
SERVICING A DOUBLE-
INSULATED APPLIANCE
In a double-insulated product, two systems of
insulation are provided instead of the grounding.
No grounding means is provided on a double-
insulated product, nor should a means for
grounding be added to the pressure washer.
Servicing a double-insulated product requires
extreme care and knowledge of the system, and should be
done only by qualified service personnel. Replacement parts
for a double-insulated product must be identical to the parts
they replace. A double-insulated product is marked with the
words "DOUBLE-INSULATION" or "DOUBLE-INSULATED".
The following symbol may also be marked on the product.
7.0
MOVING AND STORAGE
INSTRUCTIONS
C
AUTION: always store your pressure washer in a
location where the temperature will not fall below 40°F.
The pump in this machine is susceptible to permanent
damage if frozen. FREEZE DAMAGE IS NOT
COVERED BY THE WARRANTY.
8.0
TECHNICAL DATA
Pump pressure
Electrical requirement
Electrical cord
High pressure hose
Flow rate
Minimum amperage
source
Pressure of inlet water
Inlet water
Soap consumption rate
*Water flow and maximum pressure ratings determined in
accordance with PWMA. Standard PW101.
In a continued commitment to improve quality, the
Manufacturer reserves the right to make component changes
or design changes when necessary.
1500 PSI Max
*Operation pressure
120v, 15 amps, 60 Hz
23 ft.
19 ft.
1.5 GPM
15 amp
20 to 100 psi
cold tap water
10% Max
11