SYSTEM SETTING

It will be operated with the default value of the essential user settings when it is powered on for the
first time.The screen displays the following information in sequence and the user can change the value
of parameter on each screen.
When you are willing to alter the parameter value in the program, press START/ENTER to make it
blink then change the value with INC or DEC. The value will be stored by pressing START/ENTER
once.
ITEM
S a f e t y
T i m e r
O N
1 2 0 M i n
C a p a c i t y C u t - O f f
O N
5 0 0 0 m A H
T e m p C u t - O f f
O N
5 0 C
1 2 2 F
T e m p e r a t u r e U n i t
C e l s i u s
R e s t T i m e
C H G > D C H G
1 0 M i n
· 16
SELECTION
OFF/
ON
1-720 Min
(
)
OFF/
ON
(
100-50000 mAh)
OFF/
ON
(20 C/68 F -
80 C/176 F
)
Celsius
Fahrenheit
1-60Min
DESCRIPTION
When you start a charge process, the integral
safety timer automatically starts running at the
same time. This is programmed to prevent
overcharge the battery if it proves to be faulty,
or if the termination circuit cannot detect the
battery full. The value for the safety timer
should be generous enough to allow a full
charge of the battery.
This program sets the maximum charge
capacity that will be supplied to the battery
during charge. If the delta peak voltage is not
detected nor the safety timer expired by any
reason, this feature will automatically stop the
process at the selected capacity value.
The battery's internal chemical reaction will
cause the temperature of the battery to rise. If
the temperature limit is reached, the process
will be terminated.
You can choose the temperature displayed by
Celsius or Fahrenheit as you like.
A rest time allowing the battery to cool down
between charging/discharging cycle.