FONESTAR MA-400RGUZ Manual De Instrucciones página 5

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

15.- INPUT 5: line level inputs which use 2 x RCA connectors and euroblock terminals. Use the DIP
microswitches to adjust the following parameters depending on the characteristics of the signal:
The microswitch 1 (AUX 1/AUX 2) allows selection between the two input signals if both are connected.
The microswitch 2 (-10 dB PAD ENABLE) allows attenuation of the input signal in 10 dB.
When the microswitch 3 is activated (HIGH PASS FILTER) a high pass filter is introduced in the signal
path to reduce the low frequency noise.
The microswitch 4 (0 dBu/-10 dBV) allows the input signal level to be adapted depending on the type
of signal introduced.
16.- INPUT 1-4: mic./line inputs which use a combo connector (XLR and 6.3 mm jack) and euroblock
terminals. Use the DIP microswitches to adjust the input depending on the characteristics of the signal:
With the microswitch 1 (LINE/MIC) it is possible to select the sensitivity of the input, for microphone
signal or line level signal.
The microswitch 2 (PHASE) inverts the input signal phase. It is used to avoid cancellations and to correct
phase inversions due to the connection, especially for unbalanced signals.
When the microswitch 3 is activated (HIGH PASS FILTER) a high pass filter is introduced in the signal
path to reduce the low frequency noise.
The microswitch 4 (48 V PHANTOM) activates the 48 V phantom power supply for condenser
microphones.
- 5 -
EN

Publicidad

Tabla de contenido
loading

Tabla de contenido