When the flame is ignited, press ECO to lower the flame (two sound signals). Press ECO again to increase the flame
height (one sound signal).
ATTENTION! In case the device temperature is too high, the flame will be automatically lowered (ECO) and the height
regulation blocked. If the temperature keeps increasing, the device will be turned off.
Press STOP to extinguish the flame (sound signal +
You can ignite the flame again when the device is cooled – the green diode READY (
The FAST START offers faster flame ignition (when the device is ready (
The function is enabled by default.
To disable FAST START, press and hold ECO for 10 seconds (four sound signals). To enable the function, press
and hold ECO for 10 seconds (two sound signals).
ERRORS
Some alarms are accompanied by a sound signal. Press START/STOP to mute.
Lp.
DIODES
1.
2.
3.
4.
5.
6.
-
FUEL
Use only fuels consisting of 95-96,6% ethanol by volume. FANOLA
thick and viscous fuels or fuels of improper electric conductivity. The values must be compliant with those of
®
FANOLA
. Other fuels, such as dehydrated ethanol (i.e. consisting of more than 96,6% by volume ethanol) will cause
a device error and loss of the guarantee. Fuels consisting of 100% by volume ethanol will damage the device.
CLEANING
Clean with a damp cloth and delicate detergents, only when the device is turned off and cooled.
SERVICE – Keep the provided USB cable for service. Reach out to us at service@planikafires.com.
FLAME HEIGHT REGULATION
FLAME EXTINGUISHING

FAST START

(contact the Service Department if the solution does not eliminate the error)
The device is being cooled. Wait for the green diode
The device run out of fuel while operating. The device is being cooled.
Wait for the red diode to turn off. Refill the tank.
If spillage occurred while pouring the fuel, disconnect the fuel pump and wipe off the
visible liquid. Mute the device ( START/STOP button) and wait for at least one hour.
Press and hold ECO for 10 seconds. If the message does not disappear, turn off the
device and wait for a minimum of 24 hours.
If the error occurred during flame ignition, it means that the ignition time
has been exceeded. Press and hold ECO for 10 seconds.
Device error. Press and hold ECO for 10 seconds.
Tank overfilled. Contact the Service Department.
Room temperature too low (<10°C) or device error. Increase the room temperature.
Press and hold ECO for 10 seconds. Wait for the green diode
).
), the power consumption is 60 W higher).