517, 523, 529, 535, 541, 547
518, 524, 530, 536, 542, 548
585
586
587, 616, 645, 674, 703, 732
588, 617, 646, 675, 704, 733
589, 618, 647, 676, 705, 734
590, 619, 648, 677, 706, 735
591, 620, 649, 678, 707, 736
https://www.zennio.com
4 Bit
C - - T -
DPT_Control_Dimming
1 Bit
C - - T -
DPT_Switch
1 Bit
C - - T -
DPT_Switch
1 Bit
E
C - W T -
DPT_Switch
1 Byte
C - - T -
DPT_SceneControl
1 Byte
C - - T -
DPT_SceneControl
1 Bit
S
C R - T -
DPT_Alarm
2 Bytes
C - - T -
9.xxx
2 Bytes
C - - T -
DPT_Value_2_Ucount
1 Byte
C - - T -
DPT_Scaling
1 Byte
C - - T -
DPT_Value_1_Ucount
1 Bit
C - - T -
DPT_Trigger
1 Byte
E
C - W - -
DPT_Scaling
1 Byte
E
C - W - -
DPT_Scaling
1 Byte
E
C - W - -
DPT_SceneNumber
1 Byte
C - - T -
DPT_SceneControl
1 Byte
S
C R - T -
DPT_Scaling
1 Bit
S
C R - T -
DPT_Alarm
1 Bit
S
C R - T -
DPT_Alarm
1 Byte
S
C R - T -
DPT_Scaling
1 Byte
S
C R - T -
DPT_HVACMode
0x1 (Reducir 100%)
...
0x7 (Reducir 1%)
0x8 (Detener)
0x9 (Subir 100%)
...
0xF (Subir 1%)
0x0 (Detener)
0x1 (Reducir 100%)
...
0x7 (Reducir 1%)
[Ex] [Puls. Larga]
0x8 (Detener)
Aumentar/Disminuir luz
0x9 (Subir 100%)
...
0xF (Subir 1%)
0/1
[Ex] [Puls. Larga] Luz On
0/1
[Ex] [Puls. Larga] Luz Off
0/1
[Ex] [Puls. Larga] Luz On/Off
0-63; 128-191
[Ex] [Puls. Larga] Ejecutar escena Envío de 0-63
0-63; 128-191
[Ex] [Puls. Larga] Grabar escena
[Ex] [Interruptor/Sensor] Alarma:
0/1
avería, sabotaje, línea inestable
[Ex] [Puls. Larga] Valor constante
-671088,64 - 670433,28
(coma flotante)
[Ex] [Puls. Larga] Valor constante
0 - 65535
(entero)
[Ex] [Puls. Larga] Valor constante
0% - 100%
(porcentaje)
[Ex] [Puls. Larga] Valor constante
0 - 255
(entero)
[Ex] [Soltar Puls. Larga] Parar
0/1
persiana
[Ex] [Puls. Larga] Estado del
0% - 100%
regulador de luz (entrada)
[Ex] [Puls. Larga] Estado de la
0% - 100%
persiana (entrada)
0 - 63
[Detec. Mov.] Escenas: entrada
0-63; 128-191
[Detec. Mov.] Escenas: salida
0% - 100%
[Ex] Luminosidad
0/1
[Ex] Error de circuito abierto
0/1
[Ex] Error de cortocircuito
[Ex] Estado de presencia
0% - 100%
(Porcentaje)
1=Confort
[Ex] Estado de presencia (HVAC)
ALLinBOX 1612 v2 / 88 / 46 / Hospitality
> Detener regulación
Puls. Larga ->
Aumentar/Disminuir; Soltar ->
Detener regulación
Envío de 1 (On)
Envío de 0 (Off)
Conmutación 0/1
Envío de 128-191
1 = Alarma; 0 = No alarma
Valor en coma flotante
0 - 65535
0% - 100%
0 - 255
Soltar -> Parar persiana
0% - 100%
0% = Arriba; 100% = Abajo
Valor de escena
Valor de escena
0-100%
0 = No error; 1 = Circuito abierto
0 = No error; 1 = Cortocircuito
0-100%
Auto, Confort, Standby,
Soporte técnico:
https://support.zennio.com
42