Overview
1. Commissioning
1.1. Filling of the tank
❶
Open one or several hot water taps.
❷
Open the cold water tap on the security group (make sure that the drain valve is closed).
❸
When water starts flowing from the hot water taps close them. The tank is full.
❹
Check the connections for possible leaks.
❺
Check the correct function of valves and safety group by opening them several times in order to eliminate
possible particles.
1.2. First operation
If the water heater has been tilted wait for minimum 1h before operation.
Access to mode
and settings
Confirm
Increase of hot water
production