After performing the maintenance, with the hood off and the button active, press the button for more than 3 seconds to perform the
With the display on (ON) and the suction off (OFF), press simultaneously the buttons T8 and T9 for more than 3 seconds; the button
T9 lights on with steady light for approx. 5 seconds, to indicate the activation.
To disable it, repeat the operation; the button T9
Buttons T8 and T9 are not visible at this stage (on some models). They are visible only as described
in operation section of the manual.
Approximate distance of button T8 from T7 is 15 mm, and distance of button T9 from T8 is 40 mm.
Setting of Automatic Operation parameters
For correct use of the automatic operation, perform „Hood Calibration".
Hood Calibration
With the display on (ON) and the suction off (OFF), press button T3 for 3 seconds.
The suction speed (power) 2 starts functioning and button T3
15 minutes.
Note: to interrupt the calibration, press T3 for 5 seconds; the calibration will be invalidated and should therefore be repeated.
WHI643A3XGB, WHI943A3XGB, WHI643A3B
T1
T2
L1 L2 L3
To select the functions of the hood press on the symbol. Function will be activated when symbol will be released.
T1. Standby mode (the control panel off – all functions disabled) / ON (control panel switched on)
Note: After about a minute of inactivity (suction and lights), the hood will automatically switch to standby.
T2. ON/OFF lights
On certain models only (see drawing above):
press repeatedly to select the desired light intensity:
L1: low light
L2: medium light
L3: high light
Press again to turn off the lights.
T3. ON/OFF Automatic operation "AdaptTech".
The hood automatically sets the suction speed (power) 1 to increase if the environmental conditions detected by the hood sensor
require it.
If there are no variations in the environmental conditions, after 10 minutes (if the hood is already in suction speed (power) 1), the hood
turns off.
Note:
paragraph).
Note: During automatic operation, if the user acts on the other functions that adjust the speed, auto ventilation function is switched off.
T4. Manual selection of the suction speed (power):
L4: suction speed (power) 1
L5: suction speed (power) 2
L6: suction speed (power) 3
Press again to turn off the hood (OFF).
Note: manual selection excludes any other suction related set function.
T5. ON/OFF Intensive suction speed (power) "POWER BOOST" (timed)
Note: After 5 minutes of operation the hood returns to its previous state.
T6*. (Only certain models ON/OFF intensive suction speed (power) "POWER BOOST x 2" (timed)
Note: After 5 minutes of operation, the hood goes back to the previous status.
T7. ON/OFF operation mode „ReFresh".
Every 50 minutes of inactivity, the suction speed (power 1 is turned on for 10 minutes.
T8. ON/OFF Timer of the suction speed (power) (approx. 30 minutes)
Note: this function is available for the speeds that can be selected with button T4.
After performing the maintenance, with the hood off and the button active, press the button for more than 3 seconds to perform the
22 EN
T3
T4
L4 L5 L6
„Setting of the parameters for Automatic Operation" (see corresponding
T7
15 mm
T5
T6
T7
T8
T9
40 mm
T8
T9