User's manual
Customer Service
US: 1-800-645-2986
Electronic Window Air Conditioner
WARNING
Read all instructions before use.
To reduce the risk of fire, electric
shock, or injury to persons when
using this appliance, follow the
following precautions:
• Plug into a grounded 3 prong outlet.
• DO NOT remove the ground prong.
• DO NOT use a plug adapter.
• DO NOT use an extension cord.
• Unplug the air conditioner before servicing
• Two people are recommended to lift and install the unit.
• Contact a qualified service technician for maintenance
and replacement of the refrigerant R32.
The electrical ratings for your air conditioner are listed on
the model and serial number label located on the front,
left side of the unit (when facing front).
Recommended Ground Method
For your personal safety, this air conditioner must be
grounded. This air conditioner is equipped with a 3 prong
power supply cord and a grounded plug. To minimize the
possibility of electrical shock, the cord must be plugged
into a 3 prong outlet and grounded in accordance with
all local codes and ordinances. If a 3 prong outlet is not
available, it is the customers responsibility to have a
proper 3 prong outlet installed by a qualified electrician.
Manual del usuario
Servicio de atención al Cliente
US: 1-800-645-2986
Model 293133 15,000 BTU, Cool Only, Energy Star, Wi-Fi Enabled, 115V
Model 293134 18,000 BTU, Cool Only, Energy Star, Wi-Fi Enabled, 230/208V
Model 293135 24,000 BTU, Cool Only, Energy Star, Wi-Fi Enabled, 230/208V
It is the customers responsibility:
• To contact a qualified electrician
• To assure that the electrical installation is
adequate and in conformance with the National
Electrical Code, ANSI/NFPA 70 - latest edition, and
all local codes and ordinances.
LCDI Power Cord and Plug
This air conditioner is equipped with an LCD (Leakage
Current Detection and Interruption) power cord that is
required by UL. This power supply cord contains state-
of-the-art electronics that sense current leakage. If the
cord is damaged and leakage occurs, power will be
disconnected from the unit.
The test and reset buttons on the LCDI plug are used to
check if the plug is functioning properly. To test the plug:
1. Plug power cord into a grounded 3 prong outlet.
2. Press RESET (on some units a green light will turn on).
3. Press the TEST button, the circuit should trip and cut
all power to the air conditioner (on some units a green
light will turn off).
4. Press the RESET button for use. You will hear a click
and the A/C is ready for use.
1
TM
Manuel de l'utilisateur
Service à la clientèle
Canada: 888-645-2986
010522